Command: proof c_verify


Description:

Runs the carrier verification routine which consists of a drum vacuum level check and a punch hole position check. Optional ways of entering this command are:

proof c_verify <pos> - Runs the carrier verification routine with hole a position specified at <pos> (mm) from the center of the carrier plate. The drum vacuum level check uses the proof_type infomation stored in "state plate_loc proof" to fetch the vacuum-threshold parameters for the check.

proof c_verify mode - Runs the carrier verification routine. The drum vacuum level check uses the proof_type infomation stored in "state plate_loc proof" to fetch the vacuum-threshold parameters for the check. The punch hole position check also uses the proof_type infomation stored in "state plate_loc proof" to fetch the hole-position parameter.

proof c_verify mode <m> - For advanced users only. Runs the carrier verification routine. The drum vacuum level check uses the proof_type infomation stored in "state plate_loc proof" to fetch the vacuum-threshold parameters for the check. The punch hole position check uses <m> (any number from 1 to 8) to fetch the hole-position parameter. Since there will potentially be a difference between <m> and "state plate_loc proof", caution is advised.


Applies To:

  • Trendsetter_400/800_Proofing

Syntax:

proof c_verify [<pos>|mode <proof-type number>]


Notes:

When using "proof c_verify mode <m>", there is a potential for the drum vacuum check to verify one size of carrier while the hole position check the other size. There are two ways to get arround this: 1) use "proof mode c <m>" to set the desired size of carrier <m>, then use "proof c_verify mode" to verify the carrier. Both the vacuum and hole position check will use <m> as the size of the proofing carrier. 2) by-pass the vacuum check. To by-pass the vacuum check, set the vacuum sensor installed to "false" by "set alproof vsi 0" A warning message will be displayed when performing the carrier verification. Please remember to reset the vacuum sensor installed parameter by "set alproof vsi 1" To by-pass the punch hole check, set the head installed to "false" by "set sys hi 0" A warning message will be displayed when performing the carrier verification. Please remember to reset the head installed parameter by "set sys hi 1"


See Also:


Go to CTP Firmware Commands Index Page

Go to CTP Firmware Main Page