Error Message: |
ALE: Load ramp timed out moving out |
Applies to: |
|
Operator Action: |
Select the RESUME button on the workstation dialog box. If this fails to correct the problem, check that nothing is obstructing the load ramp to prevent it from moving away from the drum. If everything looks normal, then Creo Service should be called. |
Service Information: |
The load ramp out sensors failed to trip within the timeout specified by the aldly lrio parameter. There are seperate sensors for the top and the bottom of the load ramp, but only for the "away from drum" position. The sensor status may be checked by using the RAMP command. The sensor status should read TRUE if the sensors are activated. It may be useful to set the 'verbose alcmd' and 'verbose alconv' parameters to 1 in order to obtain further diagnostic information. Typing "ALE" will display the system air pressure. |
Cause:
|
See Also: |
|