Scripts were modifed and parameter values were changed to increase throughput
to 15 plates per hour. These changes also improve plate separation.
To view or to print the list of changed parameter values under
[HKEY_LOCAL_MACHINE\SOFTWARE\Scitex\Projects\Lotem400V\IO OBJECTS\Loading System...]
More...
[...\Load Plate\From Cassette To Punch Entry Stage]
X Plate Rel Backward In Cassette (mm) = 2
X Position In Cassette For Cst 3(mm) = 46
X Position In Cassette For Cst 2(mm) = 191
X Position In Cassette For Cst 1(mm) = 335
X Prepare to Catch Plate For Cst 3(mm) = 46
X Prepare to Catch Plate For Cst 2(mm) = 191
X Prepare to Catch Plate For Cst 1(mm) = 335
X Pre Extra To Short Pins (mm) = 20
Y Above Air Nozzle In Tray 2(mm) = 100
[...\Load Plate\From Punch Entry To Drum Entry Stage]
X Prepare To Drum Speed = 15
[...\Load Plate\Paper Disposal Stage]
X Paper In Motor (mm) = 640
Y Down To Paper Disposal Speed = 20
Improved plate separation
The following parameters were added to improve plate separation:
Wait For Fufu For Tray2 msec
Y Plate High Up In Cassette (Rel) For 03 (mm)
Y Plate High Up In Cassette (Rel) For 02 (mm)
Y Plate High Up In Cassette (Rel) For 015 (mm)
One CD contains all the files that were on separate CDs
and diskettes
Creo Service Port: double-click CreoServicePort.exe
ExamDiff: double-click CopyExamDiff.exe and unzip the files.
The files load to C:\Lotem\Util.
Internet Explorer: double-click ie5setup.exe (Lotem 400 Windows
95 only)
Lotem Error Log Parser: double-click copyErrorLogParser.exe
and then unzip the files. The files load to C:\Lotem\Util
NetMeeting: double-click NM30.exe (WIN 95 only. Setup instructions
are in the install.pdf file) Note: NetMeeting requires only a setup, and not a full installation.
OneClick: double-click OneClickUpdate.bat
RealVNC: double-click Vnc-3.3.7-x86_win32.exe
WinZip: double-click setup.exe
Accessories for NT (Lotem 400 Xpose only):
Modems: Drivers for analog modems used on the Lotem 400 Xpose
RAS: Follow the setup instructions in the install.pdf file
More installation guidelines are in the install.pdf file.
For Lotem 400 with MCU, after loading a plate, the XY bar moves toward the
plate to position x=700, directly over the paper/plate detector. This position
can cause a false reading. Workaround: After installation, in the registry, locate IO OBJECT\Loading
System\Load Plate\From Drum Entry to Drum Stage, and then change the X
Run Away From Plate on Drum parameter from 700 to 800.
Installing the update
Note: Lotem Controller version 1.60.09 and update 2 are prerequisites
to installing the update.
Close the Lotem Controller application.
Insert the CD (part number 651-00329A) in the CD-ROM drive.
Open the CD drive and locate the Update 3.2 folder.
Double-click setup.exe.
In the Welcome dialog box, click Next.
In the following dialog box, click Next, and then click Finish.
In the CD drive, locate the Additions folder.
Install the relevant additional files according to the installation guidelines
in the install.pdf file.
Note: Update 3.2 is also located on the downloads page, but the additions
and accessories are located only on the CD.
To test if the update is installed correctly:
Select Utilities > Machine Info. The Machine Info dialog
box should say Service Pack 3.
Click OK.
To uninstall the update:
Close the Lotem Controller application.
Select Start > Settings > Control Panel and double-click Add/Remove
Programs.
Select Lotem Update 1.60.09 u3.
Click the Add/Remove button.
At the prompt, click Yes and then click OK.
Note: Due to changes in the default values and the additional registry
parameters, readjustment of the X/Y extra parameters may be required.