These release notes describe the changes and improvements to Lotem® 400 version 1.60.09 in update 3.

Enhanced functionality

Increased throughput

Scripts were modifed and parameter values were changed to increase throughput to 15 plates per hour. These changes also improve plate separation.

To view or to print the list of changed parameter values under [HKEY_LOCAL_MACHINE\SOFTWARE\Scitex\Projects\Lotem400V\IO OBJECTS\Loading System...] More...

[...\Drum]
 Drum Low Speed (mm/sec) = 200
 Drum Speed For Unload (mm/sec) = 125
 Drum Speed For Wrapping (mm/sec) = 200

[...\Load Plate]
 Centring Wait Dis (mm) = 15

[...\Load Plate\From Cassette To Punch Entry Stage]
 X Plate Rel Backward In Cassette (mm) = 2
 X Position In Cassette For Cst 3(mm) = 46
 X Position In Cassette For Cst 2(mm) = 191
 X Position In Cassette For Cst 1(mm) = 335
 X Prepare to Catch Plate For Cst 3(mm) = 46
 X Prepare to Catch Plate For Cst 2(mm) = 191
 X Prepare to Catch Plate For Cst 1(mm) = 335
 X Pre Extra To Short Pins (mm) = 20
 Y Above Air Nozzle In Tray 2(mm) = 100

[...\Load Plate\From Punch Entry To Drum Entry Stage]
 X Prepare To Drum Speed = 15

[...\Load Plate\Paper Disposal Stage]
 X Paper In Motor (mm) = 640
 Y Down To Paper Disposal Speed = 20

Improved plate separation

The following parameters were added to improve plate separation:

One CD contains all the files that were on separate CDs and diskettes

Update 3.2 folder
Additions folder

Limitations

For Lotem 400 with MCU, after loading a plate, the XY bar moves toward the plate to position x=700, directly over the paper/plate detector. This position can cause a false reading.
Workaround: After installation, in the registry, locate IO OBJECT\Loading System\Load Plate\From Drum Entry to Drum Stage, and then change the X Run Away From Plate on Drum parameter from 700 to 800.

Installing the update

Note: Lotem Controller version 1.60.09 and update 2 are prerequisites to installing the update.

  1. Close the Lotem Controller application.
  2. Insert the CD (part number 651-00329A) in the CD-ROM drive.
  3. Open the CD drive and locate the Update 3.2 folder.
  4. Double-click setup.exe.
  5. In the Welcome dialog box, click Next.
  6. In the following dialog box, click Next, and then click Finish.
  7. In the CD drive, locate the Additions folder.
  8. Install the relevant additional files according to the installation guidelines in the install.pdf file.

Note: Update 3.2 is also located on the downloads page, but the additions and accessories are located only on the CD.

To test if the update is installed correctly:
  1. Select Utilities > Machine Info. The Machine Info dialog box should say Service Pack 3.
  2. Click OK.
To uninstall the update:

  1. Close the Lotem Controller application.
  2. Select Start > Settings > Control Panel and double-click Add/Remove Programs.
  3. Select Lotem Update 1.60.09 u3.
  4. Click the Add/Remove button.
  5. At the prompt, click Yes and then click OK.

Note: Due to changes in the default values and the additional registry parameters, readjustment of the X/Y “extra” parameters may be required.