Elevation test

The objective of the evaluation test is to find the optimal elevation angle of the optical head. A test file is exposed in resolution 100. If an elevation problem is detected in the exposed file, the elevation mechanism is adjusted until the results are satisfactory. The test results do not depend on plate type, size or thickness, therefore it can be performed on any plate the customer uses.

  1. Select the laser group that will be exposed, as follows:
  2. Choose Focus from the Calibration type menu. The Lotem calibration window for the Focus test opens (see "Focus test").
  3. Choose the optical focus value that you found in the focus test.
  4. Reduce the Intensity by 40%.
  5. For Number of Steps enter 11.
  6. Expose the test file (the first 4 beams will be exposed).
  7. Right click on the mouse to select to open the Laser group menu:
  8. Repeat steps 2 to 5. When setting the Expose parameters, enter an offset value - enter an offset value around the drum so that the batch of strips will be below the first set of strips.
  9. To determine if the elevation of the optical head is correct, you need to examine the results of the two sets of exposed strips:

Elevation adjustment:

The following explains how to adjust the optical head elevation (the numbers in brackets identify the parts shown in Figure 5-2).

  1. Connect an elevation jig [3] to the optical head.
  2. Connect a dial indicator [4] to the elevation jig.
  3. Open the three screws [2] of the optical head; open the screws until the point of friction, that is, open until the friction is strong enough to hold the optical head but still enable adjustment.
  4. Change the elevation angle of the optical head by rotating around the pin [1] and moving the optical head 0.2 mm upwards. Watch the dial indicator as you move the optical head.
  5. Close the three screws [2].
  6. Repeat the test - expose the test file and examine the results.
  7. If the test results are satisfactory, the elevation test is completed.
  8. If the test results are better than the previous results, but still not satisfactory, readjust the elevation by further moving the optical head in the same direction.
  9. If the test results are worse than the previous results, readjust the elevation by moving the optical head in the opposite direction.
  10. The test should be repeated until the elevation results are satisfactory.
  11. Secure each screw, one by one, using "Locktite" (make sure not to change the adjustment).