Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Product |
|
||
Component |
Debris removal nozzle |
||
Symptoms |
When performing a wide focus test, the debris removal nozzle may collide with the drum. This can cause severe damage to the drum, head, plate and the debris removal nozzle. |
||
Cause |
The debris removal nozzle is normally set at distance of 0.5 mm from the plate. However, when performing a wide focus test with a large focus motor range, the 0.5 mm distance between the nozzle and the plate is not great enough to prevent the nozzle from colliding with the plate. |
||
Solution |
Before performing a wide focus test, make sure that the distance between the nozzle and the plate is sufficient enough to prevent a collision. To increase the distance between the nozzle and the plate, do the following:
|
||
See also |
|||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
08 Apr 2004 |
||