Product
|
|
- Kodak ThermoFlex Mid
- ThermoFlex Narrow
|
|
Symptoms
|
|
The nozzle requires frequent cleaning, and thin black vertical lines,
or tik marks, appear on images.
|
|
Cause
|
|
- Filters in the debris removal/vacuum pump system need changing.
- The debris removal/vacuum pump hose is worn and needs to be replaced.
- The squared-off edge of the nozzle is acting as a "platform"
for ablation to sit on. The ablation particles are sticky, and build
up on the edge and internal walls of the nozzle, causing focus problems.

|
|
Solution
|
|
- Replace the filters in the Fuchs vacuum pump or UDRC, as required.
- Replace the debris
removal hose.
- Check whether the suction unit (nozzle) is the updated version (500-03854A)
or the earlier version.
Nozzle version 500-03854A (click for detail)
- Version 500-03854A: Adjust the nozzle position (step 6)
- Earlier version: You have three options:
- File down the nozzle opening (step 4)
- Update the nozzle to version 500-03854A (step 5)
- Adjust nozzle position (step 6)
- To prevent ablation from collecting, file down the edge of the nozzle
opening as follows:
- Remove the nozzle from its location by removing the two hex screws.
- Use wet sandpaper (grit P800P1000) to file down the edge of
the opening to the nozzle so that it is smooth and knife-like.
- Reinstall the nozzle.
- Update the nozzle to version 500-03854A: Remove the nozzle as described
in step 4a and install nozzle 500-03854A. Then perform the nozzle
adjustment procedure.
- Adjust the position of the nozzle so that distance between the nozzle
and the plate is 0.8-0.9 mm instead of 0.5 mm. (See nozzle
adjustment procedure.)
Note: The inside of the platesetter near the nozzle will collect
more dirt, and may require cleaning on a monthly basis.
|
|