Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Replacing the cooling unit filter on Magnus 800


Product

 

Magnus® 800


Background

 

There are different sizes of particulate filter available, depending on the UDRC configuration. This procedure is applicable for all filter sizes.


Procedure

 

Replacing the cooling unit filter:

Replace the cooling unit filter every two months. In very dusty environments, replace the filter more often.

  1. Remove the platesetter’s lower rear panel.
  2. Two fasteners are located on the left and right sides of the filter. Remove the fasteners by sliding them down and pulling them out:


  3. Gently remove the cooling filter unit from the platesetter:



  4. Install the new cooling unit filter. Make sure the arrow on the filter box points toward the platesetter.

  5. Reinstall each fastener:
    • Insert the fastener into the slot.
    • Push the fastener up:


Technical contact(s)
 

Content owner: Itai Peperovich
See the Escalation page for escalation contacts.

Date submitted
 

28 Apr 2005


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.