Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Description | Fixes and Features | Install Time and Order | Limitations | Dependencies | Workflow Compatibility | Known Problems
NOTE: You must install the version of Service Shell in this controlled release before downloading firmware in this controlled release.
This controlled release includes Thermal Head firmware version 1.93 and Media Console version 1.2.3 for Dupont customers.
CD: 651-00086B (link points to CD files on Production's master server). Order the CD from CD.Requests@Creo.com.
| Component | Version | Release Notes |
|---|---|---|
| Print Console | 3.7.1.12 | Print Console 3.7 Release Notes |
| Service Shell | 2.5 | Service Shell 2.5, 2.5 SP1 Release Notes |
| Media Console | 1.2.3 | Media Console 1.2.3 Release Notes |
| Brisque Agent | 1.00.053 | |
| Version config file TS-400-800-ContinuousLoad-MCE.INI |
1.1 | |
| MCE main firmware | 1.20.03 | Release Notes |
| XILINX/LCA/FPGA firmware for MCE | 1.79 | |
| OWP/LCA/FPGA firmware for MCE | 1.09 | |
| MCE Recovery firmware | 1.00 | Release Notes |
| MCE Boot firmware | 1.12 | |
| MCE Post firmware | 1.06 | |
| Thermal Head 1.7 firmware | 1.93 | Release Notes |
| PDB Main firmware | 1.17 | Release Notes |
| PDB Recovery firmware | 1.00 | Release Notes |
| PDB Boot firmware | 1.09 | Release Notes |
| Genine Main firmware | 1.17 | Release Notes |
| Genine Recovery firmware | 1.00 | Release Notes |
| Genine boot firmware | 1.09 | Release Notes |
| Lionel Main firmware | 1.17 | Release Notes |
| Lionel Recovery firmware | 1.00 | Release Notes |
| Lionel Boot firmware | 1.00 | Release Notes |
SAP part number for kit that includes CD plus Print Console Quick Start Guide and W2K SP4 Self Install kit: 634-00188A.
For general information about controlled releases, see the FAQ for Controlled Releases.
This controlled release updates Thermal Head firmware to version 1.93 and Media Console to version 1.2.3 for Dupont customers.
NOTE: The W2K SP4 (Windows 2000 Service Pack 4) Self Install kit should be used for updating older device control workstations because Service Shell 2.5 requires IE6 (Internet Explorer 6). This should be done before the upgrade tasks listed below.
Install in the order given. Total time - 4 hours (minimum).
Review the Dependencies before beginning. For more information see the release notes for each component.
| Task | Time |
|---|---|
For more info on Service Shell, see the SS website. |
0.25 hour |
| To upgrade firmware, including checking head and MCE f/w versions; backup parameters; download new MCE firmware; check parameters | 1 hour |
| Upgrade Print Console | 0.25 hour |
| Check that device and all applications are functional including load/unload of small/medium/large size media | 2 hours |
| Demo and provide instructions to customers | 0.5 hour |
Workflow items are not part of the release, but have been tested for compatibility.
Automatic load calibrate does not work.
The release notes for the MCE firmware included in this CR instruct you to enter command load cal to have the device set the mh DistSensorToLEC parameter during an automatic load. However, there are two problems with this command. First, it should be load calibrate (assuming the previous load was an automatic load), and second, this command does not work in this firmware release. The plate is picked, but the picker never goes down and the device hangs. Thus, it is necessary to do a manual load calibrate to set the mh DistSensorToLEC parameter:
load m 570 s 378 mi 2 ms 2 manual calibrate
mh DistSensorToLEC parameter is set and automatically saved during the load when the plate is wrapped on the drum and the device measures its mainscan size.