Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Picker actuators don't reset

Applies to
  • VLF Trendsetter AL

Machines affected All machines.

Error Number None

Component Picker

Problem The picker doesn't power up because its actuators haven't reset.

Causes and Solutions Cause 1:  Wrong signal received from firmware
Solution:
  Check that the firmware is sending the correct reset signal.

Cause 2:  Genine 2 board or driver has failed
Solution:
  See VLF Trendsetter AL Genine boards.

Cause 3:  P-cup home sensor has failed.
Solution:
 

Cause 4:  Unload finger home sensor has failed.
Solution:
Replace the unload finger home sensor. See VLF Trendsetter AL Sensors and Switches.

Cause 5:  Solenoid/valve has failed.
Solution:
  Replace the solenoid.

Cause 6:  Connections are faulty.
Solution:
  Check for poor connections or faulty wiring between:

  • Genine 2 board and the power box
  • solenoid and Genine 2 board

Cause 7:  Air supply is inadequate.
Solution:
  See Diagnosing the air supply.


Technical contact Rob Bouchal
Date submitted 10 April 2000
Date modified

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.