Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 2 Errorcode: [03540] Timeout waiting for write laser stabilization

Error details | Troubleshooting information

Thermal2 Errorcode: [03540] Timeout waiting for write laser stabilization
Thermal2 Errorcode
[03540] Timeout waiting for write laser stabilization

Service Information The commands implemented by the exposure head are non-blocking. As a result, the command to configure the write laser control mode will only initiate the write laser control mode. This error code indicates a timeout waiting for the configuration of the write laser control mode.

The first step of the configuration of the write laser control mode is to stabilize the beam-pointing and write laser diode. If the write laser diode temperature is not within normal range ( with the write laser off and the TEC's enabled ) after sixty seconds, the write laser control mode is aborted with this error code.

Operator Action Check the cooling system.

Causes
  • The write laser diode temperature is above normal ( with the write laser off and the TEC's enabled ).

Related Documents COMMAND: sys laser state
COMMAND: sys laser [on|off]
ERRORCODE: [03541] Timeout waiting for the write laser

Applies to: THERMAL2
Modified: Fri Apr 20 13:24:45 2007
Updated: Thu Jul 17 02:31:36 2008
Module: SYS

Troubleshooting information


Possible cause

 

The write laser diode temperature is above normal ( with the write laser off and the TEC's enabled ). Only out-of-range temperature can generate this error.


Suggested action

 
  1. Check for any other error messages.
  2. Check the chiller for possible failure. Even if the chiller seems to be working properly, there have been cases where the temperature servo loop has intermittent troubles.

Related Procedure(s)

 

 