| Variables | setpoint | The setpoint current from 0.0 to 83.0 amps. |
| Description | The "Current" laser diode control mode will enable the laser power supplies, enable the beam-pointing, set the laser current(s) to 120% of the threshold current(s), detect the write laser using the beam-pointing and ramp the laser current to the setpoint current. When the laser current has reached the setpoint current, the write laser has settled. | |
| Notes | Thermal 1.0 / 1.7x equivalents: | |
| ||
| Thermal 2 equivalents: | ||
| ||
| Related Documents |
COMMAND: ldd cal (dual|a|b) <setpoint> | |
|
COMMAND: ldd on (dual|a|b) <setpoint> | ||
|
COMMAND: ldd on man (dual|a|b) <setpoint> | ||
|
COMMAND: ldd man (dual|a|b) <setpoint> | ||
|
COMMAND: ldd hold | ||
|
COMMAND: ldd off | ||
|
COMMAND: ldd info | ||