Thermal3 Command
lvd info

Description Displays light valve driver information as follows:

LVD: Control Mode=<Control Mode>
LVD: Polarity Type=<Polarity Type>
LVD: Stroke Offset=<Stroke Offset>
LVD: Stroke Width=<Stroke Width>
LVD: Blocker Offset=<Blocker Offset>
LVD: Blocker Width=<Blocker Width>
LVD: Level Range for the High Polarity=<Low Level> to <High Level>
LVD: Level Range for the Low Polarity=<Low Level> to <High Level>

The light valve control mode is set by the monitor command lvd mode (plot [(high|low)]|local [(high|low)]|disable|off). The light valve control mode will be one of the following:
  • Plot
  • Local
  • Disable
  • Off

The light valve polarity type is set by the monitor command lvd mode (plot [(high|low)]|local [(high|low)]|disable|off). The light valve polarity type will be one of the following:
  • High
  • Low
  • Interleave

The NVS parameters med <media index> strokeoffset and med <media index> strokewidth configure the pixels that will be used for plotting. The NVS parameters lvd blockeroffset and lvd blockerwidth configure the pixels that are not physically blocked.

The light valve level ranges are intended to aid script development.

Notes Thermal 1.0 / 1.7x equivalents:
  • The monitor command lvd info is equivalent to head status lvd.

Thermal 2 equivalents:
  • The monitor command lvd info is equivalent to lvd info.

Related Documents COMMAND: lvd mode (plot [(high|low)]|local [(high|low)]|disable|off)
COMMAND: lvd stroke
PARAMETER: lvd blockeroffset
PARAMETER: lvd blockerwidth
PARAMETER: med <media index> strokeoffset
PARAMETER: med <media index> strokewidth

Applies to: THERMAL3
Access: FIELD
Modified: Wed Jul 16 04:28:36 2008
Updated: Wed Jul 16 04:52:22 2008
Module: LVD