Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 3 Errorcode: [08007] The stepper driver is active

Error details

Thermal3 Errorcode: [08007] The stepper driver is active
Thermal3 Errorcode
[08007] The stepper driver is active

Service Information The monitor commands act initialize, act shutter (open|close) and act actuate <index> <steps> will wait a maximum of thirty seconds for the actuation of the stepper driver to complete. This error code indicates that the previous actuation of the stepper driver is not complete.

Operator Action Call service.

Causes
  • The maximum acceleration and / or the maximum speed is too low.
  • Hardware failure of the stepper driver.

Related Documents COMMAND: act initialize
COMMAND: act shutter (open|close)
COMMAND: act actuate <index> <steps>
PARAMETER: act shutteracceleration
PARAMETER: act shutterspeed
PARAMETER: act blockeracceleration <index>
PARAMETER: act blockerspeed <index>

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:28 2008
Updated: Wed Jul 16 04:52:16 2008
Module: ACT