Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 3 Errorcode: Thermal3 Errorcode: [01024] Focus drive system not initialized

Error details

Thermal3 Errorcode: [01024] Focus drive system not initialized
Thermal3 Errorcode
[01024] Focus drive system not initialized

Service Information Before the auto focus servo system can operate it must determine the mechanical and electrical integrity of its actuator hardware. The central method of checking the actuator hardware is through a 'focus initialization' operation. This occurs automatically at system power up and may be invoked manually with the 'foc init' command.

Focus initialization moves the auto focus lens tube actuator through various expected degrees of freedom while using all possible means to reduce the risk of lens damage due to excessive acceleration caused by unexpected malfunctions.

Auto focus initialzation can fail for many reasons few of which are easlily recoverable but most of which are not. If initialization is not successful many subsequent auto focus monitor commmands may fail.

Operator Action Call service.

Causes
  • Focus drive system not initialized.
  • The air pressure connected to the head is low or disconnected.

Related Documents COMMAND: foc init
COMMAND: foc cal lvdt
ERRORCODE: [01020] Timeout initializing focus lens tube
ERRORCODE: [01021] Excessive travel during focus lens tube init
ERRORCODE: [01022] Insufficient travel during focus lens tube init
ERRORCODE: [01023] Focus lens actuator offset current out of range
ERRORCODE: [01023] Focus lens actuator offset current out of range

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:31 2008
Updated: Wed Jul 16 04:52:15 2008
Module: FOC

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.