Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 3 Errorcode: [05211] Timeout waiting for the write laser to be detected

Error details

Thermal3 Errorcode: [05211] Timeout waiting for the write laser to be detected
Thermal3 Errorcode
[05211] Timeout waiting for the write laser to be detected

Service Information To protect the exposure head, initially the laser current is limited to 120% of the threshold current for each laser diode. The beam-pointing driver then attempts to begin tracking the write laser. This error code indicates that a timeout has occured waiting for the beam-pointing driver to begin tracking the write laser.

Operator Action Call service.

Causes
  • The threshold current is too low.
  • A hardware failure of the exposure head.

Related Documents COMMAND: ldd setup
COMMAND: ldd characterize [(a|b)]
PARAMETER: ldd slopeefficiencya
PARAMETER: ldd thresholdcurrenta
PARAMETER: ldd slopeefficiencyb
PARAMETER: ldd thresholdcurrentb

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:35 2008
Updated: Wed Jul 16 04:52:15 2008
Module: LDD

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.