Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 3 Errorcode: [05814] The diagnostic function is not supported

Error details

Thermal3 Errorcode: [05814] The diagnostic function is not supported
Thermal3 Errorcode
[05814] The diagnostic function is not supported

Service Information A subset of the diagnostic monitor commands require specific satellite board(s) to be present. This error indicates that the required satellite board(s) are not present.

Operator Action Only enter diagnostic monitor commands that are supported by the hardware configuration.

Causes
  • Verifying the bias linearity requires the LVDL satellite board to be present.
  • Displaying the bias voltage requires the LVDL satellite board to be present.
  • Sampling the pulse amplifiers on the LVDU satellite board requires the LVDU satellite board to be present.
  • Sampling the pulse amplifiers on the LVDL satellite board requires the LVDL satellite board to be present.
  • Sampling the pulse amplifiers on the LVDU and LVDL satellite boards requires the LVDU and LVDL satellite boards to be present.

Related Documents COMMAND: lvd linearity lvbias
COMMAND: lvd volts lvbias
COMMAND: lvd pasample (<offset> <width>|all) [(lvdu|lvdl)] [continuous]

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:36 2008
Updated: Wed Jul 16 04:52:20 2008
Module: LVD

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.