Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 3 Errorcode: [02009] The parameter copy is invalid

Error details

Thermal3 Errorcode: [02009] The parameter copy is invalid
Thermal3 Errorcode
[02009] The parameter copy is invalid

Service Information When the parameter subsystem registers the table of parameters from other subsystems, the number of copies of the table of parameters can also be specified. This error indicates that the user has specified an invalid copy.

If the subsystem specifies one copy of the parameters, the user must not specify the copy when accessing one of the parameters. For example, the light valve driver subsystem specifies one copy of the light valve driver parameters. Thus the user must not specify the copy.

If the subsystem specifies multiple copies of the parameters, the user must specify the copy when accessing one of the parameters. For example, the media subsystem specifies sixteen copies of the media parameters ( for the initial version ). Thus the user will specify copies from 0 to 15.

Operator Action Verify the previous monitor command and enter a valid copy.

Causes
  • The copy is invalid.

Related Documents COMMAND: set <subsystem> [<copy>] <parameter> [(<element>|all)] <value>
COMMAND: set <subsystem> [<copy>] [<parameter>]

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:38 2008
Updated: Wed Jul 16 04:52:20 2008
Module: PRM