Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 3 Errorcode: [05650] Health metric(s) have faulted

Error details

Thermal3 Errorcode: [05650] Health metric(s) have faulted
Thermal3 Errorcode
[05650] Health metric(s) have faulted

Service Information The exposure head will monitor a variety of health metrics ( temperatures, voltages, pressures, etc ) and shutdown the exposure head if required. To allow operation of the exposure head to continue, the user can mask any combination of health metrics to prevent the exposure head from being shutdown. This error code indicates that the launching of a plot has either been prevented or would be prevented by a health metric.

It is undesireable to mask health metrics. Masking a health metric implies that there is either a hardware failure in the exposure head or the range checking performed by the firmware is invalid. Regardless, the underlying problem should be fixed; not masked.

Note that the monitor command adc will display the health metrics and the monitor command hlt mask (on|off) <index> will configure the fault mask's.

Operator Action Verify all health metrics in the exposure head. If necessary, a health metric can be masked in the exposure head.

Causes
  • System monitoring of the health metrics has detected as least one fault in the exposure head.

Related Documents COMMAND: adc [(hc|npe|act|pbp|ibs|dbp|wlc|rfe|lvdu|lvdl|pbp2|lvdp|lvdn)]
COMMAND: hlt mask [(on|off) <index>]

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:39 2008
Updated: Wed Jul 16 04:52:16 2008
Module: SYS