Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Escalation

Service call escalation process | RC RSS2s | Regional PSSs | See Also

Service call escalation process

The escalation procedure for logging a service call for a head-related problem is as follows:

  1. Call your local Response Center (US&C 1-877-788-2727).
  2. On-duty Response Center staff (RC2) will contact you and attempt to solve the problem by:
    • Checking the Thermal 3 Head Troubleshooting page
    • Checking for any similar Thermal 3 calls in SAP CRM and/or AskMe
  3. Before escalating to Product Development, you must collect the information in the table below (15 minutes or less to complete).
  4. If the RC2 staff can’t solve the problem, they will escalate to the Product Development Escalation Manager.

If you need to return a head, follow the procedure How to Return a Head.

  What to do Notes
1 FedEx a plate sample to head office. Do this immediately. Send to:
Kurt Shelton
4225 Kincaid Street
Burnaby, B.C.
V5G 4P5
Canada
2 Record the case number. Include:
  • Customer name
  • Customer location (city, country)
3 Record the names of the on-site FSE and the Regional Escalation contact. Regional PSS (see the table below)
4 Record the machine type. Include:
  • Serial number
  • Firmware version
5 Record the head type. Include:
  • Serial number
  • Firmware version
6 Record the media type. Include the batch number.
7 Indicate if a debris removal nozzle is installed and record a description of the final window and debris nozzle condition, using a visual inspection. Include any relevant details, such as date of last cleaning. Refer to the window cleaning procedure normally performed during troubleshooting (for details see Cleaning the Thermal 3 Final Lens and Debris Removal Nozzle).
8 Include a Beam Balance graph. Obtained during normal troubleshooting procedure. In Splot or Service Shell, run BeamBalance.spt. If Beam Balance does not run correctly, run bbsprofile.spt instead.
9 Include a ContvBP graph. Obtained during normal troubleshooting procedure. In Splot or Service Shell, run contvBP.spt
10 Include a BPD Noise graph. Obtained during normal troubleshooting procedure. In Splot or Service Shell, run BPDNoise.spt.
11 Include existing NVS settings. Obtained during normal troubleshooting procedure. In Splot or Service Shell, run NVSDump.spt
12 Record the problem history. Include:
  • problem details
  • work performed
  • parts replaced
  • call duration

If you are authorized to return a head,
follow the correct procedure (Ordering a replacement head). See also Thermal head experts authorized for head replacements.

Note: Once the problem has been solved, share the wealth! Submit details about the problem and solution using the Submit Troubleshooting Info link at the top of this page.

Response Center Contacts

See also Thermal head experts authorized for head replacements.

RC2 Engineers

Darren Brant US&C RC2 (Burnaby) Local 2990 Mobile 604-617-6205
Rick Hsu US&C RC2 (Burnaby) Local 2024 Mobile 604-351-0623
Ciprian Nistor US&C RC2 (Burnaby) Local 2114 Mobile 604-374-8634

Regional PSSs/PSMs

Note: If you are working in US&C, escalate to the RC2 engineers.

Alexandre Duvieusart EAMER PSS Local 8322 2917 Mobile +32.497.51 2917
Direct Line +32.2.352 2917
Andrew Dunn APR PSS (Hong Kong) Direct Line +852 2839-8810 Mobile +852-9091-8755
Masaki Ueda KJP Direct Line 81-3-5259-9495 Mobile 81-90-4168-4923
Takeshi Hamada KJP Direct Line 81-6-6203-6887 Mobile 81-90-5199-6540

See also