Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Downloads


Problems downloading? More...

If your file does not open correctly after downloading: breaks in data transmission during file transfers are common when network traffic is high. A break and subsequent restart may cause an error at the restart point, which results in a corrupt transfer. The end result is a file that does not open or run correctly. For example, *.exe files may not run, *.pdfs may not open, and *.zip files may be reported as invalid archives. The simplest solution is to retry downloading the file. If the problem persists, try to download the file when network traffic is lighter.

Updates | Plug-ins | Utilities

Updates

major upgrade | minor updates

Application Description Download
Prinergy Update Utility (PPU)
(18 Mar 2004)

Before downloading any 2.2 major or minor updates, the latest version of the PPU must be installed. See the Prinergy 2.2 Upgrade Guide (English) and FAQ: Prinergy Update Utility (PPU) for instructions.

Note: To install or remove any major or minor update using this PPU, the Prinergy system must be in Maintenance Mode. Placing the system in Maintenance Mode prevents backups from running while you are installing/removing updates. See the Prinergy 2.2 Upgrade Guide (English) for instructions.

Prinergy Update Utility
PUpdate.exe PUpdate.exe, the Prinergy update application, is the software used for upgrading to Prinergy 2.2 and applying major and minor updates. Prinergy Update Application
PreCheck.exe PreCheck.exe, the Prinergy Pre-Installation Requirement Check application, alerts the customer to potential conflicts that they should take care of before attempting to apply the Prinergy 2.2 upgrade. PreCheck.zip includes the PreCheck.exe and PreCheck.py files. Prinergy PreCheck application

Major Upgrade

For information about Prinergy 2.2 prerequisites and instructions for upgrading a Prinergy system to 2.2.1.y, see the Prinergy 2.2 Upgrade Guide (English).

Major Upgrade Description Download
2.2.1.0
(17 Sep 2003)
For details about this major upgrade, see the Prinergy 2.2.1.0 Readme. Prinergy 2.2.1.0 upgrade .ppu file

Minor Updates

For information about Prinergy 2.2 prerequisites and instructions for updating a Prinergy system to 2.2.1.y, see the Prinergy 2.2 Upgrade Guide (English).

Minor Update Description Download
2.2.1.12
(28 Oct 2004)
For details about this minor update, see the Prinergy 2.2.1.12 Readme. Prinergy 2.2.1.12 Minor Update.
2.2.1.11
(20 Aug 2004)
NOTE: This update switches all existing proof and plate JTPs to use the 3016 RIP. The 3011 RIP is no longer available in this or subsequent updates. Note that for the following devices, a direct connection to the 3016 RIP is not supported: Heidelberg Hercules, Primesetter, Quasar, Signasetter, Topsetter and Speedway Engine Manager. These devices will be supported in a future update. For details about this minor update, see the Prinergy 2.2.1.11 Readme. See also: Prinergy 2.2 and later: Adobe CPSI 3016 RIP - Customer information and instructions for using the Adobe CPSI 3016 RIP with Prinergy 2.2.1.8 and later. Click here to download CJK font bundles for use with the Adobe CPSI 3016 RIP. Prinergy 2.2.1.11 Minor Update.
2.2.1.10
(16 Aug 2004)
For details about this minor update, see the Prinergy 2.2.1.10 Readme. Prinergy 2.2.1.10 Minor Update.
2.2.1.9b
(08 Jun 2004)
2.2.1.9b replaces 2.2.1.9, posted 31 May 2004. For details about this minor update, see the Prinergy 2.2.1.9 Readme. Prinergy 2.2.1.9 Minor Update.
2.2.1.8
(11 May 2004)
For details about this minor update, see the Prinergy 2.2.1.8 Readme. See also: Prinergy 2.2 and later: Adobe CPSI 3016 RIP - Customer information and instructions for using the Adobe CPSI 3016 RIP with Prinergy 2.2.1.8 and later. Click here to download CJK font bundles for use with the Adobe CPSI 3016 RIP. Prinergy 2.2.1.8 Minor Update.
2.2.1.7
(01 Apr 2004)
For details about this minor update, see the Prinergy 2.2.1.7 Readme. Prinergy 2.2.1.7 Minor Update
2.2.1.6c
(06 May 2004)
Prinergy 2.2.1.6c has some changes for customers with CJK fonts installed. It replaces 2.2.1.6b, which was posted on 04 Apr 2004. For details about this minor update, see the Prinergy 2.2.1.6c Readme. Prinergy 2.2.1.6c Minor Update
2.2.1.5
(06 Feb 2004)
For details about this minor update, see the Prinergy 2.2.1.5 Readme. Prinergy 2.2.1.5 Minor Update
2.2.1.4
(07 Jan 2004)
For details about this minor update, see the Prinergy 2.2.1.4 Readme. Prinergy 2.2.1.4 Minor Update
2.2.1.3
(01 Dec 2003)
For details about this minor update, see the Prinergy 2.2.1.3 Readme. Prinergy 2.2.1.3 Minor Update
2.2.1.2
(27 Oct 2003)
For details about this minor update, see the Prinergy 2.2.1.2 Readme. Prinergy 2.2.1.2 Minor Update
2.2.1.1
(21 Sep 2003)
For details about this minor update, see the Prinergy 2.2.1.1 Readme. Prinergy 2.2.1.1 minor update

Plug-ins

Name Description Download
Creo Distiller Assistant This plug-in adds extra functionality to Adobe’s Acrobat Distiller via a PostScript startup file. See the Kodak Distiller Assistant (also bundled with the download) for more information. Mac versionWindows version

Utilities

Name Description Download
Kodak System Check Tool The Kodak System Check Tool collects all software and system information and attaches this information to an escalation call. The tool can be used by customers or Kodak personnel. The Kodak System Check Tool will be included in Prinergy 3.1.0.5 and later and can be used with older versions of Prinergy. The System Check Tool Technical Bulletin explains how to install and run the tool, how to view the files, and the structure of the HTML and compressed files. Kodak System Check Tool
Nettest tool Nettest.exe is a fast, first-check tool for measuring network performance between two servers in the same configuration. If a problem is found, further diagnosis can be performed using Netperf.exe (located in the support\bin folder on all Prinergy servers). Nettest.exe will be included in Prinergy 3.1.0.5 and later (in the support\bin folder) and can be used with older versions of Prinergy. Nettest tool
Rehosting a Primary Server ZIP file This ZIP file contains the scripts and utilities necessary to complete the rehosting procedure as described in Rehosting a Prinergy 2.x Primary Server. Rehosting a Primary Server ZIP file
lanacfg.exe utility

There is an invalid assumption in our code that eth adapter 0 will always be present in a customer's machines. If the old eth adapter is replaced by a new one, during an upgrade to Prinergy 2.2 for example, the new one may not be assigned number 0 by NetBIOS. You can use the lanacfg.exe utility to rearrange the numbering of the newly installed adapters so that adapter 0 is always present in the system. This will prevent the error message: E ... ExtremeSerialNumberFromMACAddress: NetBios NCBRESET error: rc=35

To use this utility: More...

  1. Download (and unzip) the lanacfg.exe utility.
  2. Execute the command: lanacfg.exe showlanapaths.
  3. Take note of the Lana number for your adapter reported by the utility (for example, Lana: 3).
  4. Set the Lana number of your adapter to 0: lanacfg.exe setlananumber 0. For example, in the above case of eth number being 3, use: lanacfg.exe setlananumber 3 0.
  5. Update the registry with new settings: lanacfg.exe rewritelanainfo.
  6. Restart the computer.
  7. (Optional) Verify the new Lana number is 0 by executing: lanacfg.exe showlanapaths.

lanacfg.exe utility

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.