Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Problems downloading? More...
If your file does not open correctly after downloading: breaks in data transmission during file transfers are common when network traffic is high. A break and subsequent restart may cause an error at the restart point, which results in a corrupt transfer. The end result is a file that does not open or run correctly. For example, *.exe files may not run, *.pdfs may not open, and *.zip files may be reported as invalid archives. The simplest solution is to retry downloading the file. If the problem persists, try to download the file when network traffic is lighter.
Updates | Plug-ins | Scripts | Utilities
| Name | Description | Download |
| VPS 2.2.2 Mac | Kodak Virtual Proofing System 2.2.2 installer for Mac OS X | Kodak Virtual Proofing System 2.2.2 installer for Mac OS X |
| VPS 2.2.2 Windows | Kodak Virtual Proofing System 2.2.2 installer for Windows | Kodak Virtual Proofing System 2.2.2 installer for Windows |
| Application | Description | Download |
| Prinergy Update Utility (PPU)
(06 Apr 2006) |
Before downloading any 3.0 major or minor updates, the latest version of the PPU must be installed. For more information see the FAQ: Prinergy Update Utility (PPU). Note: To install or remove any major or minor update using this PPU, the Prinergy system must be in Maintenance Mode. Placing the system in Maintenance Mode prevents backups from running while you are installing/removing updates. |
Prinergy Update Utility |
| PUpdate.exe
(06 Apr 2006) |
PUpdate.exe, the Prinergy update application, is the software used for upgrading to Prinergy 3.0 and applying major and minor updates. | Prinergy Update application |
| PreCheck.exe
(06 Apr 2006) |
PreCheck.exe, the Prinergy Pre-Installation Requirement Check application, alerts the customer to potential conflicts that they should take care of before attempting to apply the Prinergy 3.0 upgrade. Use PreCheck.exe only for the Prinergy 3.0 major upgrade. Do not use it for minor updates. PreCheck.zip includes the PreCheck.exe and PreCheck.py files. | Prinergy PreCheck application |
| Major Upgrade | Description | Download |
| 3.0.3.0
(10 Jan 2006) |
For details about this major
upgrade, see Prinergy 3.0.3.0 Readme.
Note: Prinergy 2.3 and 3.0.2.y users can upgrade directly to 3.0.3.0 using this file. Note for users of Preflight: In Prinergy 3.0.3.0, if Preflight is on and ColorMatch is configured to convert spots to process, in some circumstances Prinergy will erroneously report the spot as being still present, although the file will be CMYK only. The workaround is to do a minimal 2nd Refine. This issue will be fixed in Prinergy 3.0.3.1. Note: Prinergy 3.0.2.x users upgrading to 3.0.3.0 who are running or have tested Rules-Based Automation, should run the Precheck utility to check for active rules. If an active rule is found, delete the rule from your rule set before beginning the upgrade. If your Rules-Based Automation license has expired, contact the Response Center to have them delete the rule. Note: Sites using PostScript Bypass workflow that need to export jobs to other sites are advised that the PostScript Bypass content is not included in job exports in Prinergy 3.0.3.0. This will be fixed in Prinergy 3.0.3.1. | Kodak fast download link |
| Minor Update | Description | Download |
|
|
Note: Prinergy 2.x and 3.0.2.x users can upgrade directly to 3.0.3.0. | |
| 3.0.3.1e
(21 Apr 2006) |
For details about this minor update, see Prinergy 3.0.3.1 Readme. Note: The Edit Copy button function in the 2ndRefine Color Mappings dialog box is broken in Prinergy 3.0.3.1. The workaround is to manually add the color in the job color library. | Prinergy 3.0.3.1e Minor Update Kodak fast download link |
| 3.0.2.4
(04 Oct 2005) |
For details about this minor
update, see Prinergy 3.0.2.4 Readme.
|
Prinergy 3.0.2.4 Minor Update |
| 3.0.2.3
(24 Aug 2005) |
For details about this minor
update, see Prinergy 3.0.2.3 Readme. Note: Users of Synapse Insite 4.2 PressProof and Smart Review with page RIPing - These features do not work with Prinergy 3.0.2.3 and should be fixed in the next update.
|
Prinergy 3.0.2.3 Minor Update | 3.0.2.2c
(19 July 2005) |
For details about this minor update, see the Prinergy 3.0.2.2 Readme. Note: Sites running UNIX tertiaries - Jobs homed on UNIX tertiaries will not open in Workshop on OS X in 3.0.2.2. This is fixed in 3.0.2.3. Note: Sites using "File Mover/Renamer" type Smart Hot Folders - "File Mover/Renamer" type Smart Hot Folders do not work in 3.0.2.2. ("Job Creator" type Smart Hot Folders are not affected.) This is fixed in 3.0.2.3. Note: Warning! Do not upgrade Prinergy or Prinergy Evo sites connected to Veris 1.6 until updated Veris software is available The Certified Process option in Prinergy 2.3.1.4, 3.0.2.2, and Prinergy Evo 3.0.0.53 does not work with Veris 1.6.904 and earlier. Do not upgrade sites to this configuration until an updated Veris software version is available. This software is expected to be available Aug. 3, 2005, and will require a service call. For more information on the issue, see the Creo Certified Process for Proofing in Creo Workflows document on the Veris Connectivity page. |
Prinergy 3.0.2.2 Minor Update |
| 3.0.2.1
(02 May 2005) |
For details about this minor update, see the Prinergy 3.0.2.1 Readme. | Prinergy 3.0.2.1 Minor Update |
| Name | Description | Download |
| Creo Distiller Assistant | This plug-in adds extra functionality to Adobe’s Acrobat Distiller via a PostScript startup file. See the Kodak Distiller Assistant (also bundled with the download) for more information. | Mac version Windows version |
| Acrobat 7.0 Plug-ins | This section contains download files for Acrobat 7.0 PDF Compare and PDF Merge Plug-ins. | Mac Version Windows Version |
| Acrobat 7.0 Plug-ins |
This section contains information about Acrobat 7.0 plug-ins for Prinergy users for Geometry Editor, Separation Repair Tool, View Accelerator, Preflight Locator, CreoToolsPro (Trap Editor, DotShop and Separations Viewer). For detail information, see the Prinergy Acrobat Plug-ins for Adobe Acrobat 7.0 technical bulletin. Installing the Prinergy Adobe Acrobat 7.0 plug-ins on Mac:
Installing the Prinergy Adobe Acrobat plug-ins on PC:
|
Acrobat 7 Plug-in (Mac) Acrobat 7 Plug-in (PC) |
| Name | Description | Download |
| Rename.zip | For renaming a Prinergy 3.x or 4.x server. Contains python scripts to rename the registry and configuration files. File includes: RegistrySearchAndReplace.cmd, FileSearchAndReplace.cmd, fileinput.py, fnmatch.py, and Regfind.exe. Use with the appropriate procedure: | Rename.zip |
| Name | Description | Download |
| Kodak Prinergy 3.x Rehosting Tool v1.15 | The Kodak Prinergy 3.x Rehosting Tool automates the process of rehosting a Prinergy 3.x server and is for use only by Kodak personnel. This tool will not be included in any minor update. To use it, you must download and install it from this location. This tool can only be used to rehost a Prinergy 3.x server to a Prinergy 3.x server. The Prinergy 3.x Rehosting Tool WebEx provides a quick overview (download the appropriate WebEx player here). The Rehost Tool for Kodak Prinergy Software explains how to install and run the tool. Note: If you use the rehosting tool during the next few months, please send your feedback to Dirk De keersmaecker. | Kodak Prinergy 3.x Rehosting Tool |
| Rehosting a Primary Server ZIP file | This ZIP file contains the scripts and utilities necessary to complete the rehosting procedure as described in Rehosting a Prinergy 3.x Primary Server. | Rehosting Utilities ZIP |
| Kodak System Check Tool | The Kodak System Check Tool collects all software and system information and attaches this information to an escalation call. The tool can be used by customers or Kodak personnel. The Kodak System Check Tool will be included in Prinergy 3.1.0.5 and later and can be used with older versions of Prinergy. The System Check Tool Technical Bulletin explains how to install and run the tool, how to view the files, and the structure of the HTML and compressed files. | Kodak System Check Tool |
| Kodak Get Server Info Tool | The Get ServerInfo tool collects diagnostic information from the server and stores it in a ServerInfo folder. The customer or a Kodak service representative runs the tool from the server desktop. For information on installing and running the tool, see the GetServerInfo readme. | Kodak Get Server Info tool |
| Kodak Duplicate RSM Tool | The Duplicate RSM tool merges the RSM database from one system to another. It is helpful when migrating the RSM database from Windows 2000 to Windows 2003. It also allows you to merge RSM databases across many servers for redundancy. For information on the tool, see the DuplicateRSM readme . |
Duplicate RSM tool |
| Kodak List Tapes and Pools Tool | The List Tapes and Pools tool locates the media pools and the tapes associated with each media pool. For information on the tool, see the ListTapesAndPools readme. | List Tapes and Pools tool |
| Nettest tool | Nettest.exe is a fast, first-check tool for measuring network performance between two servers in the same configuration. If a problem is found, further diagnosis can be performed using Netperf.exe (located in the support\bin folder on all Prinergy servers). Nettest.exe will be included in Prinergy 3.1.0.5 and later (in the support\bin folder) and can be used with older versions of Prinergy. | Nettest tool |
| lanacfg.exe utility | There is an invalid assumption in our code that eth adapter 0 will always be present in a customer's machines. If the old eth adapter is replaced by a new one, during an upgrade to Prinergy 2.2 for example, the new one may not be assigned number 0 by NetBIOS. You can use the lanacfg.exe utility to rearrange the numbering of the newly installed adapters so that adapter 0 is always present in the system. This will prevent the error message: E ... ExtremeSerialNumberFromMACAddress: NetBios NCBRESET error: rc=35 To use this utility: More...
| lanacfg.exe utility |