This document presents the possible causes and solutions for Dolev 4press error
messages starting with the letters A-C. For more error message solutions, see
Error Message Guide D-N (under construction).
| ACC Buffer too Large - Film has accumulated
between unloading rollers and unload cassette. |
| Description and possible cause |
Solution |
- Unload cassette encoder loose, tight, or stuck
- Unload cassette motor does not rotate properly
- Light seal assy shutter does not open properly
|
- From the utility, advance 100 mm of film.
- Cut and collect the film.
- Empty accumulative cassette.
- Open side doors and clear film path.
- Verify that unload cassette motor rotates properly.
- Verify that gear sprockets are interlaced.
- Verify that light seal shutter opening, when open, is 2-3 mm.
- Verify that buffer parameter is the recommended value.
- Run the motor graph function and verify that all encoders are intact.
|
| ACC Cassette Full - The accumulation cassette
is full. |
| Description and possible cause |
Solution |
|
More than the maximum amount of film has accumulated (18 meters for 4
mil film, 10 meters for 7 mil film.
Back to top of page
|
- Cut and collect the film, and process it.
- Insert an empty unload cassette
|
| Another User Online |
| Description and possible cause |
Solution |
|
Imagesetter occupied by one channel while the second channel attempts
connection.
|
Wait.
|
| Asked too Long Film |
| Description and possible cause |
Solution |
|
The request to advance film (manual or via host) exceeds the maximum
amount of film allowed to the conveyor.
Back to top of page
|
- Use Cut and Service utility to cut excessive film.
- Remove excess film from conveyor.
- Reboot the imagesetter.
- Verify that the total length (image width, margins, offsets) of the
advance requested does not exceed the allowed range (250630 mm).
|
| Asked too Short Film |
| Description and possible cause |
Solution |
|
The request to advance film (manual or via host) is less than the minimum
amount of film allowed to the conveyor.
|
- Reboot the imagesetter.
- Verify that the total length (image width, margins, offsets) of the
advance requested is not less than the allowed range (250630 mm).
|
| Attach Film Crash |
| Description and possible cause |
Solution |
|
A film crash may have occurred in the drum during the attachment sequence
related to:
- Edge of film not cut straight
- Motor setting parameters outside default value range
- Malfunction of film encoder
- Load/unload rollers do not rotate properly
- Online conveyor pulls film during attachment sequence
Back to top of page
|
- Advance film about 300 mm. If error message persists, proceed to
step 2.
- Perform Change Media to unload film from the drum and open
the drawers.
- Reload film.
- Open the two side doors.
- Manually rotate load and take rollers, and check that the load and
take encoders make one full rotation per roller rotation. If they do
not, adjust spring or replace encoder.
- If on-line processor is connected, verify that conveyor does not pull
film.
- In the setup, check the following parameters against the motor setting
table and reduce parameter values, if required.
- Relief parameter0,0.
- Motor velocity parameterclose to default value.
See also: Attach film crash - vibrations
|
| Bad Communication |
| Description and possible cause |
Solution |
|
Error in communication between host and imagesetter related to:
- Imagesetter internal error
- Imagesetter microversion
- Host cable
- Host internal error
- TSP/VLSI board
- HOMC board
|
- Reset the imagesetter, and try to expose.
- Update to the latest microversion.
- Replace the host cable.
- Reboot, or perform Host cold start.
- Check if a TSP error message exists, and resolve.
- Replace the HOMC board.
|
| Board Config Error |
| Description and possible cause |
Solution |
|
Electronic boards do not match imagesetter configuration because the
HCRI board is the old configuration.
Back to top of page
|
- Verify that the latest microversion
is installed, and update if required.
- Replace the HCRI or ACRI board, and add a Strobe
board.
- Reboot the imagesetter.
|
| Capture Film Crash |
| Description and possible cause |
Solution |
|
Unloadin/accumulative cassette has not grasped the film related to:
- Unexpected piece of film remains in unloading cassette
- Unloading cassette motor assembly malfunction of gears, position detector,
or motor
Back to top of page
|
- Verify that the latest microversion
is installed, and update if required.
- Advance 100 mm of film.
- Perform Change Media.
- Open the unloading drawer and check if there is any film remaining
in the unloading cassette. If any film remains, process it or dispose
of it, as required.
- To see if the carriage functions properly, move the carriage from
HP to EP and back, and verify that there is not too much slack between
the gears.
- If there is too much slack, replace the unloading cassette motor assembly.
- Move the carriage again and check that the position detectors function.
|
| Carriage Already Move |
| Description and possible cause |
Solution |
|
An attempt is made to move the carriage while the carriage is already
in motion. The CRI board may be causing this error message.
Back to top of page
|
- Reboot or reset the imagesetter.
- To see if the carriage functions properly, move the carriage from
HP to EP and back.
- Run diagnostics for CRI.
- Replace the CRI board.
|
| Carriage In Motion |
| Description and possible cause |
Solution |
|
Conflicting software tasks related to carriage movement.
|
Perform shutdown and restart the imagesetter.
|
| Carriage isn't Moving |
|
Description and possible cause
|
Solution |
|
No carriage movement, related to:
- Stepper motor
- Cable connections
- CRI board problem
Back to top of page
|
- Run diagnostics for the following:
- Driver batch test
- Machine batch test
- Check the adjust the cable connections, if required.
- Replace the stepper motor.
- Replace the stepper driver.
- Replace the CRI board.
|
| Carriage Lost Location |
| Description and possible cause |
Solution |
|
Occurs during plotting or return to HP related to:
- Cables faulty or loose
- File or media crash
- Lead screw loose
- Stepper motor malfunction
- CRI board losst correct counting of the stepper motion
Back to top of page |
- Check and adjust the cables, if required.
- Check inside the drum for film or foreign objects, and remove, if
required.
- Verify that there is not too much freedom between the dynamic optic
assembly and the leadscrew, and adjust, if required.
- Check the function of the stepper motor,
and replace it, if required.
- Replot.
- Replace the CRI board.
|
| Carriage Stuck at EP |
| Description and possible cause |
Solution |
|
The carriage does not leave end position, related to:
- Stepper motor wiring
- EP detector wiring
- EP detector
- CRI board
- Stepper driver
- Stepper motor coupling
Back to top of page |
- Check and adjust the stepper motor wiring, if required.
- Verify that the EP detector cable is connected to the detector.
- Verify that the EP detector is functioning
properly, and replace it, if required.
- Reboot the imagesetter.
- Manually move the carriage from EP by turning off the imagesetter
and rotating the leadscrew from the left side.
- Verify that both interlocks are pushed in.
- Replace the CRI board.
- Replace the stepper driver.
- Replace the stepper motor coupling.
|
| Carriage Stuck at HP |
| Description and possible cause |
Solution |
|
The carriage does not leave home position, related to:
- Stepper motor wiring
- HP detector wiring
- HP detector
- CRI board
- Stepper driver
- Stepper motor coupling
- Power converter
Back to top of page |
- Check and adjust the stepper motor wiring, if required.
- Verify that the EP detector cable is connected to the detector.
- Verify that the EP detector is functioning
properly, and replace it, if required.
- Reboot the imagesetter.
- Manually move the carriage from EP by turning off the imagesetter
and rotating the leadscrew from the left side.
- Verify that both interlocks are pushed in.
- Replace the stepper motor coupling.
- Replace the stepper driver.
- Replace the CRI board.
- Replace the power converter.
|
| CASM Overload |
| Description and possible cause |
Solution |
|
Accumulative cassette motor overload - the motor cannot rotate, and the
current has reached overload limit, related to:
- Film stuck in cassette motor assy
- Unload motor not functioning
|
- Perform "cut and collect"
- Open the unloading drawer manually, if required.
- Remove the accumulative cassette.
- Verify that there is no film or other foreign object stuck in the
cassette motor assembly.
- Verify that the cassette rotates freely. If it does not, replace the
unloading cassette assembly.
|
| Course Calib Fault |
| Description and possible cause |
Solution |
|
Light calibration error, related to problem with:
- Values in RES/INT table out of limits
- Static optic unit
- HOMC board
Back to top of page
|
- Try to expose the same file again.
- Verify that the file resolution is within the limits.
- In the RES/INT table, verify that all values are within the maximum
limits of the static optic unit.
- Run the NDF graph, and verify that the laser value is above 40,000.
- If the laser value is less than 40,000, replace the static optic
unit.
- If there is no result in the graph, check and replace the following,
if required:
- Fiber optic quick connectors
- Light detector board
- Light detector
- Replace the HOMC board
|
| CRI 400Krz Err |
| Description and possible cause |
Solution |
|
400 KHZ synthetic clock on CRI board not detected in CRI start-up tests
during power-on or restart related to CRI board problem.
|
- Run diagnostics for CRI batch test.
- Replace the CRI board.
|
| CRI acc request Err |
| Description and possible cause |
Solution |
|
Stepper accumulation logic error, detected in CRI start up tests during
power-on or restart
Back to top of page
|
- Run diagnostics for CRI batch test.
- Replace the CRI board.
|
| CRI Encoder Frame Err |
| Description and possible cause |
Solution |
|
Incorrect number of encoder pulses per index. Wrong frequency from the
encoder, related to problem with:
- Spinner motor wiring
- Encoder power wiring
- Encoder clock wiring
- Standard controller connectors
- J3 connector/CRI board
- Spinner motor encoder
- Spinner
|
- Restart the imagesetter.
- Check wiring/connectors for the following, and fix if required:
- Spinner motor
- Encoder power
- Encoder clock
- Standard controller
- Replace the CRI board.
- Replace the spinner.
|
| CRI > IS Comm. Err |
| Description and possible cause |
Solution |
|
CRI does not respond
Back to top of page
|
- Replace the CRI board.
- Replace the CPU board
- Replace the standard controller.
|
| CRI Illegal Acc Err |
| Description and possible cause |
Solution |
|
CRI illegal accumulation error related to program algorithm
|
- Increase expose resolution.
- Replace the CRI board.
|
| CRI line control Err |
| Description and possible cause |
Solution |
|
(For internal diagnostic use)
|
- Reboot.
- Replot the same file.
|
| CRI Load Error |
| Description and possible cause |
Solution |
|
During startup, problem loading hardware table related to problem with:
- CRI board
- CPU board
- Standard controller
|
- Replace the CRI board.
- Replace the CPU board.
- Replace the standard controller.
|
| CRI micro StepDAC err |
| Description and possible cause |
Solution |
|
During startup and reset, digital to analog conversion error related
to problem with CRI board
Back to top of page
|
- Run CRI batch test.
- Replace the CRI board.
|
| CRI Pll Division Err |
| Description and possible cause |
Solution |
|
During Prepare Plot, PLL out frequency error related to problem with
CRI board
|
- Run CRI batch test.
- Replace the CRI board.
|
| CRI Pll Freq. Err |
| Description and possible cause |
Solution |
|
During Prepare Plot, PLL out frequency error related to problem with
CRI board
|
- Run CRI batch test.
- Replace the CRI board.
|
| CRI Pll Setup Err |
| Description and possible cause |
Solution |
|
Error in PLL calculated setup, PLL factor is out of range (3-254) related
to incorrect data parameters.
Back to top of page
|
- Check file resolution parameters.
- Try different spinner speeds.
|
| CRI Polarity ram err |
| Description and possible cause |
Solution |
|
Error in checking the CRI board micro steps related to CRI trigonometric
parameters.
|
Set the default parameters for the stepper motor
table. |
| CRI stepRam err |
| Description and possible cause |
Solution |
|
Error in checking the CRI board micro steps related to problem with CRI
board.
Back to top of page
|
- Run CRI batch test.
- Replace the CRI board.
|
| CRI Startup Failed |
| Description and possible cause |
Solution |
|
During startup, CRI does not achieve standby status related to:
- Other error messages
- CRI board problem
|
- Check and resolve the other error messages.
- Replace the CRI board.
|
| CRI StopCond int err |
| Description and possible cause |
Solution |
|
During the start of microstep, if the action is stopped, the error message
indicates an error in the stop condition signal.
|
- Reset the imagesetter.
- Check and resolve the other error messages.
|
| CRI StopCond sig err |
| Description and possible cause |
Solution |
|
Carriage movement stops, related to error in stop condition signal
Back to top of page
|
- Reset the imagesetter.
- Check and resolve the other error messages.
|
| CRI WCS Load Error |
| Description and possible cause |
Solution |
|
During startup, problem loading software program, related to:
- CRI board
- CPU board
- Standard controller
|
- Replace the CRI board.
- Replace the CPU board.
- Replace the standard controller.
|
| CRI WCS Missing |
| Description and possible cause |
Solution |
|
CRI.wcs file is missing, related to corrupt microversion
|
Reinstall the latest microversion.
|
| CRI WCS RAM Err |
| Description and possible cause |
Solution |
|
CRI system microprocessor memory error
Back to top of page
|
Replace the CRI board.
|
| CRI XIL Missing |
| Description and possible cause |
Solution |
|
CRI.xil file is missing, related to CRI board problem
|
Replace the CRI board.
|
| CUTM Overload |
| Description and possible cause |
Solution |
|
The cutter motor current has reached the overload limit and the cutter
motor cannot rotate, related to:
- Cutter chain tension
- Wide sprocket stuck on shaft
- Cutter assembly cannot move smoothly on guide rods
- Cutter knives are dull
- DC motor controller board
Back to top of page |
- Check the cutter chain tension, and adjust, if required.
- Replace the guide sprocket assembly.
- Disassemble the cutter, clean and grease the rods and the custter
plastic bearings, and then reinstall the cutter.
- Replace the cutter motor.
- Replace the DC motor controller.
|
| Cutter Detectors Err |
| Description and possible cause |
Solution |
|
Incorrect cutter position, or problem with cutter detectors, related
to:
- Cutter HP/EP detectors malfunction
- Cutter chain broken
- Sprocket stuck
- Bent flag on cutter
- Cutter motor malfunction
- DC motor controller board
|
- Check if the cutter chain is worn or broken, and replace the chain,
if required.
- Remove the cutter chain and verify smooth rotation of the sprocket
wheel. If the wheel does not rotate smoothly, replace the sprocket assembly.
- Verify that the flag on the cutter signals the detectors properly,
and adjust the flag, if required.
- On the detector status screen, check detector functionality, and replace
HP or EP detector, if required.
- Replace the cutter motor.
- Replace the DC motor controller.
|
| Cutter isn't in HP |
| Description and possible cause |
Solution |
|
The cutter is not in Home Position, related to:
- Cutter chain tension
- Wide sprocket stuck on shaft
- Cutter assembly cannot move smoothly on guide rods
- Cutter knives are dull
- DC motor controller board
Back to top of page |
- Check the cutter chain tension, and adjust, if required.
- Replace the guide sprocket assembly.
- Disassemble the cutter, clean and grease the rods and the custter
plastic bearings, and then reinstall the cutter.
- Replace the cutter motor.
- Replace the DC motor controller.
|
| Cutter Stuck |
| Description and possible cause |
Solution |
|
The cutter is not in Home Position, related to:
- Cutter leading rods
- Cutter HP/EP detectors malfunction
- Cutter chain broken
- Sprocket stuck
- Bent flag on cutter
- Cutter motor malfunction
- DC motor controller board
Back to top of page |
- Try to cut again.
- Clean the cutter leading rods and oil them with silicon oil, and then
verify that the cutter moves freely from side to side.
- Open the side doors and verify that nothing is blocking the cutter.
- Move the cutter manually from side to side.
- Move the cutter manually to HP.
- Verify that both detectors are connected.
- On the detector status screen, check detector functionality, and replace
HP or EP detector, if required.
- Replace the cutter chain.
- Remove the cutter chain and verify smooth rotation of the sprocket
wheel.
- Verify that the flag on the cutter signals the detectors properly.
- Replace the cutter motor.
- Replace the DC motor controller.
|
| For more error message
solutions, see Error Message Guide D-N |