Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Dolev 800/800V/800VČ TIC -  Installation
Punch/On-Line Conveyor

Installation

Punch Assemblies Final Adjustments

See FCO17436 -   05/05/93 Light Area Harness
See FCO 17851 -   15/06/93 Manifold installation
See FSB 378 -   19/01/94 Changes on Punch units
See FCO 18908 -   09/03/94 Punch Basket Big R
See -   09/12/96 Dolev 800 Calibration with the Brisque
See -   26/01/97 Dolev 800 Punch Calibration with the Brisque

Overview
Film Cassette Positioning
Punch Hole Linearity Adjustment
Final Values Check
Locking the Punch Assemblies

Overview

Refer to: Punch Assembly Parts
Punch Hole Linearity Dimensions
Linearity Indicator Holder
Final Plot Check
Locking the Assembly Adjusting Screw

This section describes final alignment of punch holes. It assumes that the punch sequence operates satisfactorily, and that punch hole distances are correct. You will need to perform several plots during this procedure. Most time will be spent on peripheral activities such as cover and gauge placement and removal, plotting, film development, and measurement of result

Punch holes should be co-linear within 0.01 - 0.02 mm. The best method for testing compliance to this requirement is use of an accurate digital measuring table. If such a table is available, a plotted and punched film sheet is simply measured and punch hole locations are subsequently adjusted directly.

Since such measuring tables are generally not available at the customer site, a second method is used which produces acceptable results. This method involves plotting of a calibration grid which is used as reference for linearity. This method ignores image bow, which may be up to 30 microns. When the distances from the punch holes to the grid lines are measured, it is easy to determine how each punch assembly adjustment screw should be moved. When adjustments are complete, the final punching line should be parallel to the image within 0.2 mm. The procedures following describe use of this method.

An indirect adjustment method entails mounting the punched film onto the customer's pinbar and observing the mating quality of the pins to the holes. However, this "eyeball" method lacks accurate feedback for making subsequent punch assembly adjustments.

Film Cassette Positioning

  1. Attach the medium and large film rollers to the right flange of the cassettes.

  2. Attach the medium and large cassettes to the right wall of the loading/unloading system.

  3. Load large film and measure the width of film which extrudes, unsupported, from the right drum interior. Take several measurements from different loaded films for maximum accuracy.

    Repeat this procedure for the medium film cassette.

  4. Compare the various measurements. The unsupported film width for both medium and large films should be from 25 to 28 mm. In case of a larger dimension, attach the correct film roller to the cassette's left flange. Instruct the customer to install the film roller in the same way that it is loaded now, including the way the cassette is loaded into the loading system. Check the results.

Punch Hole Linearity Adjustment

  1. Prepare the Imagesetter for plotting:
  1. Install the covers (without screws)
  2. Load film into the cassette
  3. Prepare the film processor
  4. Activate the air pressure
  1. Prepare a calibration plot file. Use one of the following methods:
    Create a line of 20 microns in thickness along the film height direction, located in the vicinity of the punch holes; or
    Use the Plot Grid option from the Tools package. Specify a Height Offset value of 754, with all remaining fields at that default values.

  2. Plot the calibration file, specifying Yes to the Punch option, with a known offset. Process the plotted film.

  3. Examine the processed film. Measure the dimensions depicted in Compare them to the customer's Punched Film Layout Form:
  1. Distance from the film edge to the punch hole center (Px dimension for every punch hole); and
  2. Distance from the plotted line to the film edge.

    Punch Hole Linearity Dimensions

    punchlin.gif (4426 bytes)

        Plot and measure at two (2) films for highest accuracy.
  1. Refer to the customer-approved punch layout and calculate the corrections necessary for Px at each punch. Write down these values for reference in later steps. Be careful not to confuse punch holes.

  2. If the f dimension is not between 0.2 and 1 mm, an adjustment in plot Height Offset will be necessary. If so, calculate the correction necessary in the plot Height Offset by using the following example:

    Given:    Ix = 17.9 mm (measured from film edge)
                   Px = 12 mm (specified in layout)
                   d = 6.35 mm (punch hole diameter, specified in layout)
                   f = 0.2 mm (optimal value for manual microscope measurement)
                   current height offset = 10 mm
    Then:     new height offset     = current height offset + Ix + Px - d/2 - f
                   12.525 = 10 + 17.9 - 12 - 6.35/2 - 0.2

    If the new height offset calculates to a negative number, change the plotted image file to compensate, perform a new plot, and measure I again.

  3. Install the linearity indicator holder (Cat. No. 290B36736) on the first punch assembly.

    Remove the punch mouth (Refer to ) from the assembly by loosening its two (2) #6 securing screws, and replace its with the indicator holder. (The securing holes are slotted to allow quick removal. There is no need to remove the screws.)

  4. Using the punch utilities on the control panel, perform a UNIT IN movement.

  5. Install the indicator gauge into its place in the holder. Refer to The indicator tip should rest on the punch assembly base. Reset the indicator gauge to zero.

    Linearity Indicator Holder

    lineindic.gif (4454 bytes)

  6. Loosen the punch assembly adjusting screw. (Refer to ) Slowly rotate the adjusting screw (thereby changing the UNIT IN position) until the indicator reading is identical to the value calculated in Step 9. Be sure to lock the 1/4- inch securing nut following the adjustment.

    Caution: 1. When adjusting the 1/4-inch securing nut, hold the punch assembly firmly to minimize loads on the linear bearing. 2. Do not perform a UNIT IN/OUT with the indicator installed. This may damage the indicator's delicate mechanism.

  7. Remove the indicator and perform UNIT OUT.

  8. Repeat Steps 11-14 for all punch assemblies. When completed, perform UNIT OUT and return to the Standby prompt in the Imagesetter operating panel.

Final Values Check

  1. Plot the calibration file once again. When requested as part of the plot dialog, specify the new Height Offset calculated in Step 10.

  2. Using a ruled microscope, measure all IP distances, as specified in Microscope resolution accuracy should be within 0.02 mm.

    Final Plot Check

    finplot.gif (3853 bytes)

    Note: Perform at least one plot on large film and one plot on medium film.

  3. Check that Px1 through Px10 are identical to their corresponding Px values in the punch layout. Allow a maximum tolerance of 2 mm.

  4. Check IP1 through IP10. The maximum allowed variation in IP is 20 microns. Repeat Steps 11 through 17 should the variation exceed this value.

  5. Once all measured Px and IP values are acceptable, proceed with an inspection of the mating quality of the punched film on the customer's pinbar.

Locking the Punch Assemblies

  1. When positioning of all punch units is completed, lock the adjusting screw securing nuts of each assembly into place by applying Loctite. The locking material should be applied in two places along the adjusting screw.

    Locking the Assembly Adjusting Screw

    lockasss.gif (2145 bytes)

  2. Add all installation paperwork (e.g., Punch Film Layout Forms, Customer-approved Layout, Order List, etc.) to the on-site Dolev technical folder. Be sure to include handwritten calculations.
  3. This completes the final adjustment of the punch system. You should now plot some actual customer files to observe the overall registration quality of the Imagesetter.

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.