Background
|
|
In order maintain throughput and to diagnose problems caused by
actuators acting too slowly or too quickly, it is useful to know:
- How to measure the timing of the actuators
- Which actuators are field-adjustable
- How to adjust any actuators whose timing is out of spec.
|
|
Procedure
|
|
Engine time
| Picker time | Table
time
-
In Service Shell’s Device Monitor
command box, type:
engine time
-
The device reports engine actuator timing
information.
-
Examine the table below to determine
whether the timing of all actuators is within spec. If not,
and if the actuator timing is field-adjustable, click the
green bullet • to go to
the page showing the regulator to adjust for that actuator.
| Actuator |
Base, AL, CL,
NEWS |
Field-
adjustable? |
| Timing spec (milliseconds) |
Tolerance (±) |
| LEC down |
450 |
Check for evenness |
|
| LEC up |
300 |
50 |
|
| Roller down |
450 |
Check for evenness |
|
| Roller up |
300 |
50 |
|
| Ramp in |
1050 |
Check for evenness |
• |
| Ramp out |
500 |
Check for evenness |
• |
| TEC down |
1100 |
Check for evenness |
|
| TEC unlock |
400 |
50 |
|
| TEC lock |
250 |
50 |
|
| TEC up |
250 |
50 |
|
|
|
|
|
-
In Service Shell’s Device Monitor
command box, type:
picker time
-
The device reports picker actuator timing
information.
-
Examine the table below to determine
whether the timing of all actuators is within spec. If not,
and if the actuator timing is field-adjustable, click the
green bullet • to go to
the page showing the regulator to adjust for that actuator.
|
| Actuator |
NEWS 50, 70,
100, 150 |
NEWS 200 |
TS AL |
Field-
adjustable? |
| Spec |
± |
Spec |
± |
Spec |
± |
| Rot1 |
Non-rot2 |
| Picker up |
52003 |
500 |
32003 |
500 |
52003 |
500 |
• |
| Picker in |
3300 |
500 |
3000 |
500 |
3000 |
500 |
• |
| Picker wrist in |
5000 |
3500 |
500 |
1700 |
500 |
5000 |
500 |
|
| Picker wrist out |
10000 |
2000 |
4000 |
500 |
10000 |
2000 |
|
| Picker out |
2100 |
250 |
2250 |
250 |
2100 |
250 |
• |
| Picker down |
2000 |
250 |
1800 |
250 |
2000 |
250 |
• |
| Separator in4 |
Check for evenness |
Check for evenness |
Check for evenness |
• |
| Separator out4 |
Check for evenness |
Check for evenness |
Check for evenness |
• |
|
Notes:
1. Devices with rotator
2. Devices without rotator
3. Picker up time applies to GMCE/TMCE devices
that have FCO CA11580 (new
picker up/down sensors) installed.
4. Plate separator option is only enabled on full format
NEWS devices and Trendsetter Autoloaders. |
|
|
|
-
In Service Shell’s Device Monitor
command box, enter command:
table time
-
The device reports table actuator timing
information.
-
Examine the table below to determine
whether the timing of all actuators is within spec. If not,
and if the actuator timing is field-adjustable, click the
green bullet • to go to
the page showing the regulator to adjust for that actuator.
| Actuator |
AL, CL, NEWS |
Field-
adjustable? |
| Timing spec (milliseconds) |
Tolerance (±) |
| Table down |
9000* |
1000 |
|
| Table cups up |
700 |
100 |
|
| Table rot on |
3000 |
500 |
• |
| Table rot off |
3000 |
500 |
• |
| Table cups down |
700 |
100 |
|
| Table up |
5525 |
500 |
|
Note:
* Assumes table is in the up position when table time