Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 2 Errorcode: [02336] The transmission of WLP burst data is not supported

Error details | Troubleshooting information

Thermal2 Errorcode: [02336] The transmission of WLP burst data is not supported
Thermal2 Errorcode
[02336] The transmission of WLP burst data is not supported

Service Information The laser diode setpoint temperature will default to 25 degrees C but can be temporarily modified by the monitor command ldd setpoint <temperature>. This error indicates that configuration of the laser diode setpoint temperature is not supported.

Note that the WLP must be enabled to determine the WLP firmware version. The WLP is disabled if the control mode of the laser diode driver is "Reset" or "Simulate".

Operator Action Call service.

Causes
  • The WLP is disabled.
  • The WLP firmware does not support the transmission of WLP burst data.
  • The exposure head hardware does not support the transmission of WLP burst data.

Related Documents COMMAND: ldd mode (calibrate|monitor|power|retrace|suspend|current|simulate|reset|_standby|off) [<setpoint>]
COMMAND: ldd info
COMMAND: ldd setpoint <temperature>
COMMAND: ver
PARAMETER: ldd wlpsetpoint

Applies to: THERMAL2
Modified: Thu Aug 30 16:19:16 2007
Updated: Thu Jul 17 02:31:36 2008
Module: LDD

Troubleshooting information


Possible cause

 

This error indicates that configuration of the laser diode setpoint temperature is not supported.


Suggested action

 
  1. Check the write laser status using the command:
    ldd info.
  2. Type the command:
    Th2 > ldd mode off.
  3. Try again.
  4. Check for other errors.
  5. Contact your RC or Product Support Specialist.