Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 2 Errorcode: [02334] The laser power is unstable

Error details | Troubleshooting information

Thermal2 Errorcode: [02334] The laser power is unstable
Thermal2 Errorcode
[02334] The laser power is unstable

Service Information The "Power" and "Retrace" laser diode control modes will attempt to maintain the laser power by adjusting the laser current. This error indicates the laser power is unstable.

Note that this error code is also returned to the host as an unsolicited warning fault.

Operator Action Call service.

Causes
  • The laser power is unstable.

Related Documents COMMAND: ldd mode (calibrate|monitor|power|retrace|suspend|current|simulate|reset|_standby|off) [<setpoint>]

Applies to: THERMAL2
Modified: Thu Aug 30 16:19:16 2007
Updated: Thu Jul 17 02:31:35 2008
Module: LDD

Troubleshooting information


Possible cause

 

M8 is out by 2% or more.


Suggested action

 
  1. If the fault is intermittent, run shtrglitch.spt.
  2. Check the nafion air line.
  3. Check the 48 V power supply to the write laser.
  4. If this error comes with one or more of the following other errors: 02333, 02332, or 02326, check the write laser current when the laser is on. Use the command ldd info.
    If the current value is close to or over the nominal current, try reducing head power.
  5. Check the bpd sensors by running bpdnoise.spt.
  6. If the warning persists, contact the RC.

Related Procedure(s)

 