Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Troubleshooting Tip | Laser Problems | BPD Errors | LDD Errors | LV Errors | BBS Errors
If a TH2 head is experiencing problems while trying to beam balance, it does not necessarily mean that the BBS sensor or subsystem is at fault. Laser profile and beam position problems may be reflected in a failure to do a stroke cal. The best way to identify the fault is to set all subsystems involved in the stroke cal process to verbose, then try the stroke cal again and observe the resulting error. The subsystems invlolved are BPD, LDD, LVD and BBS.
Once you have a better idea of which subsystem may be causing the problem, use the procedure below to test that subsystem. Some of the most common causes of stroke cal failure are discussed in detail below.