Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 3 Errorcode: [05210] The calibrated values are out-of-range

Error details

Thermal3 Errorcode: [05210] The calibrated values are out-of-range
Thermal3 Errorcode
[05210] The calibrated values are out-of-range

Service Information Setup of the laser power controller includes algorithms to automatically calibrate a variety of NVS parameters. This error indicates the automatically calibrated NVS parameter(s) are out-of-range.

Operator Action Call service.

Causes
  • Insufficient signal from the laser diode sensor.
  • A hardware failure is corrupting the A/D samples.
  • Firmware error that will occur during firmware development and testing.

Related Documents COMMAND: ldd setup
COMMAND: ldd characterize [(a|b)]
COMMAND: ldd tune
PARAMETER: ldd kp
PARAMETER: ldd ki
PARAMETER: ldd kb
PARAMETER: ldd slopeefficiencya
PARAMETER: ldd thresholdcurrenta
PARAMETER: ldd slopeefficiencyb
PARAMETER: ldd thresholdcurrentb

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:35 2008
Updated: Wed Jul 16 04:52:19 2008
Module: LDD