Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Brisque 3.0.38 or 4.0 produces CT Images with identical process values 


Product

  FreeHand 8.0 and 9.0

Brisque 3.0.38 and 4.0

Platform

  Macintosh

Operating system

 

IBM AIX 4.2.1 and IBM AIX 4.3.3


Symptoms

  CT images with identical process values for all the separations are produced from the Brisque RIP.

Cause

  If you save TIFF/JPEG images created in a FreeHand 8.0 and 9.0 page as DCS2.0 (from the FreeHand 8.0 and 9.0 application), the RIP process in Brisque will produce a CT image with identical process values for all the separations. This also occurs if you interfere manually by keeping only the Cyan separation.

Or:

If you create DCS2.0 files in  FreeHand 8.0 and 9.0 and place them inside a QuarkXPress page to create a pre-separated PostScript file, the RIP process in Brisque will produce a CT image with identical process values for all the separations.

This also occurs with the Harlequin RIP.


Solution

  These are known limitations in Brisque 3.0.38 and Brisque 4.0.

See also

 

For information on known limitations on DCS2.0 files created in the following DTP Applications:

Freehand 8 and 9:

PageMaker 6.5

QuarkXPress 3.3 and 4.x

Or, using the DCS2.0 files in the general Brisque workflow:


Technical contact(s)
 

Viki Bar-On

Submitted by
 

Viki Bar-On

Date submitted
 

13 Aug 2001


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.