Solution
|
|
Check edge detection performance
- From the PC Controller application, run
the edge detection test. Accuracy should be 0.01 mm.
- While the edge detection test is running, check the MCF
slave sproc zoh_average.out, and check stability of the values received
during drum rotation.
If the data value varies, it indicates that the edge detection
reading is not stable due to one of the following being incorrect:
- focus
- power
- strip location
Steps 8-10 below describe how to resolve these issues.
Note: Step 2 must be completed while the edge detection test
is running or the results will be inaccurate.
- Check the reliability and accuracy of the edge detection test:
- Load a plate.
- Expose two intensity strips along the drum (height axis) on each
side of the plate.
- Unload the plate.
- Repeat steps a-c, 5 to 10 times.
- Process the plate.
When the loading system is properly aligned, and edge detection is properly
aligned, a 10 µ line is not widened to more than double its
width.
Troubleshooting
Throughout the procedure below, after any modification or change of parameters,
check the edge detection performance again, as described above. If the
error message persists, continue the troubleshooting procedure.
- Clean the following:
- Lens
- Drumwith vacuum on, clean drum vacuum holes
- Light detector
- Edge detection stripclean with alcohol
- Check plate attachment to the drum.
- Confirm that the vacuum pump is turned on, and correct if required.
- If hot spots or bubbles occur in the leading edge of the plate,
use the following procedures to resolve these problems.
- If positive plates are used, check the Fufu Air Pump parameter in
the registry to confirm that it is closed, and correct if required.
Note: Many edge detection problems result from fufu
air contamination due to oil, water, and other dirt.
- Check that the Plate Thickness parameter is correctly
defined in the media definition, and correct if required.
- In the Expose registry, check that the value of the Focus
Relative Move for Edge Detection parameter is 100 for
0.15 and 0.2 mm plates.
- If your plate is close to the maximum allowed plate size, confirm
that the Height Start Image Area parameter is smaller
than the expected edge detection parameter. Reduce the Height
Start Image Area parameter by 3 to 5 mm, if required.
- In the Expose registry, check the Plate on Drum Height Axis
Absolute Position Error parameter. This parameter represents
the area along the drum in which the edge is expected to be found. The
default of 20 can be increased to 40 or 60.
Note: This parameter is important, especially if you
do not center the plate in the semi-manual machine.
If you increase the number too much over 50, you may encounter further
edge detection errors due to drum dirt or obstacles. For example, if
you have a full-sized plate and the number is set to 60, the edge detection
could detect the drum edge as a plate.
- Check the focus motor functionality by checking the coarse
and the fine HP adjustments and the focus motor function.
- Check
the power using the test panel. Increase or decrease the laser power
according to the stability of the results.
- In the edge detection registry, check
the lower and upper limit values for strips 1 and 2, which
define the window in where the edge is found around the drum.
- If you have a 24-diode device, check the functionality of beam 0.
This beam determines proper edge detection. If required, in the edge
detection registry, select beam 23 instead of beam 0, or, replace diode
0.
Note: If you have a 12-diode device, only beam 0 determines
proper edge detection. Ensure that beam 0 is functioning, and replace
it, if required. Ensure that all diodes are functioning, and replace
any defective diode, if required.
- Check the cable and fiber connections to the following boards.
If there are no problems with the connections, replace the boards.
- On the connector on the MCF side (pins 8 and 15), measure the ED analog
output voltage. With laser 0 ON at about 40 mW, the output should be
approximately 0 V.
Note: The output on the drum should be approximately 5 V.
If the voltage is not correct, replace the edge detection board.
|