Update 3.1 and additions - release notes for Lotem 400 Quantum, version 1.50.08

The Update 3.1 release notes describe the changes and improvements to version 1.50.08 in update 3. The release notes include the following sections:

Enhanced functionality

Improved throughput

To achieve a rate of 25 plates per hour, scripts were modifed and parameters were changed.

The following parameters were added:

The following parameters were changed:

To view or to print the list of changed parameter values under [HKEY_LOCAL_MACHINE\SOFTWARE\Scitex\Projects\Lotem400V\IO OBJECTS...] More...

In ...\Loading System, the default values of the following parameters were changed:
  • Y Up Before Back Abs (mm)—default is 14
  • Sleep After Extra to Detector [mm]—default is 1500 (was 2000)
  • X Extra To Short Pins (mm)—default is 10 (was 40)
  • X Extra To Short Pins For 02 (mm)—default is 8 (was 20)
  • Time To Wait In Punch Before Stop Paper Dis[Msec]—default is 1500 (was 2000)
  • Time To Sleep After Extra In cassette [mSec]—default is 1000 (was 1500)

In ...\VERSION:

  • Main Version Number=1.50.08
  • Service Pack=3

In ...\Loading System\Drum

  • Drum Speed For Unload (mm/sec)=125
In ...\Loading System\Load Plate
  • Centring Wait Dis (mm)=14

In ...\Loading System\Load Plate\From Cassette To Punch Entry Stage

  • Time To Sleep After Plate Seperation [mSec]=1000
  • Wait For Fufu msec=1000
  • X Extra To Short Pins (mm)=15
  • X Plate Rel Backward In Cassette (mm)=2
  • Y Up For Verify Plate=-30
  • X Extra To Short Pins For 02 (mm)=8
  • Time To Wait In Punch Before Stop Paper Dis[Msec]=1500

In ...\Loading System Setup

  • Sleep After Extra to Detector [mm]=1500

In ...Loading System\Load Plate\From Drum Entry to Drum Stage

  • Height For Small Plate Extra To Drum (mm)=300
  • X Run Away From Plate On Drum=400

In ...Loading System\Load Plate\From Punch Entry To Drum Entry Stage

  • X Prepare To Drum Speed=15
  • Y To Drum (mm)=40
  • Y Up After DoPunch For 0.15=40
  • Y Up After DoPunch For 0.2=50
  • Y High Up Speed=10

In ...\Loading System\Load Plate\Paper Disposal Stage

  • Delay For Y Up (Mili Sec)=500
  • Time To Sleep After Extra In cassette [mSec]=500
  • Time To Sleep Before Stop Paper Disposal [mSec]=0
  • Y Paper High Up In Cassette Speed=10

In ...\LOCAL 3\Local 3 Card

  • TimeOut For Embedded Communication [mSec]=700

In ...\LOCAL 3\VALVE\Unload Gripper Valve

  • Application On Time [mSec]=
  • On Time [Msec]=0

In ...\LOCAL 3\VALVE\Unload Roller Valve

  • Application On time [Msec]=50

In ...\LOADER\VALVE\Plate Ramp Valve

  • Application On time [Msec]=100

In ...\LOADER\VALVE\Small Plate Suction Valve

  • Application Off time [Msec]=200

In ...\LOADER\VALVE\XY Suction Valve

  • Application Off time [Msec]=0

In ...\LOADER\VALVE\Large Plate Suction Valve

  • Application Off time [Msec]=0

In ...\NEW LOCAL\SOLENOIDS\Unload Gripper Valve

  • Application On Time [mSec]=0
  • On Time [Msec]=0

Improved plate separation

The following parameters were added to improve plate separation:

One CD contains all the files that were on separate CDs and diskettes

Load these manually from the CD:

Update 3.1 folder
Additions folder

Limitations

For Lotem 400 with MCU, after loading a plate, the XY bar moves toward the plate to position x=700, directly over the paper/plate detector. This position can cause a false reading.
Workaround: After installation, in the registry, locate IO OBJECT\Loading System\Load Plate\From Drum Entry to Drum Stage, and then change the X Run Away From Plate on Drum parameter from 700 to 800.

Known Bugs

After you install service Shell, in Diagnostics, the drum section is not supported.

Installing update 3

Note: Lotem Controller version 1.50.08 is a prerequisite to installing update 3.

  1. Close the Lotem Controller application.
  2. Insert the CD (part number 651-00330A) in the CD-ROM drive. The update self-installs.
    If for any reason the update does not self-install, proceed as follows:
    1. Open the CD drive folder and double-click setup.exe.
    2. In the Welcome dialog box, click Next.
    3. In the following dialog box, click Next, and then click Finish.
    Update 3.1 saves the following to folder C:\TH2\tools. Note: To load to the head and TMCE, see Loading a Patch to TMCE.
  3. After restart, in the Registry, browse to IO Objects\Local 3\Local 3 Card change the TimeOut for Embedded Communication [mSec] parameter from 700 to 3000.
  4. In the CD drive, locate the Additions folder.
  5. Install the relevant additional files according to the installation guidelines in the install.pdf file.

Note: Update 3.2 is also located on the downloads page, but the additions and accessories are located only on the CD.

To test if the update is installed correctly:
  1. Select Utilities > Machine Info. The Machine Info dialog box should say Service Pack 3.
  2. Click OK.
To uninstall the update:
  1. Close the Lotem Controller application.
  2. Select Start > Settings > Control Panel and double-click Add/Remove Programs.
  3. Select Update 3 Lotem Update 1.50.08 u3.
  4. Click the Add/Remove button.
  5. At the prompt, click Yes and then click OK.

Note: Due to changes in the default values and the additional registry parameters, readjustment of the X/Y “extra” parameters may be required.