Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Checking and adjusting the Lotem 800 family platesetter’s covers, panels and doors


Product

 

Lotem® 800 family platesetters with Omron® interlocks


Background

 

This procedure describes how to utilize jigs to check and adjust the following:

  • Depth of interlock key belonging to the top-front cover, top-rear cover, left-side door, and unload panel.
  • Positioning of interlock belonging to the top-front cover, top-rear cover, left-side door, and unload panel.

Requirements

 
  • Lotem 800 doors and interlocks adjustment jigs kit (part number 518-01578A)
  • Rear cover jig (part number 690-00721A)
  • Digital voltmeter (part number xxx)
  • Interlock jig cable (part number 220-01407A)

Procedure

 
  1. If required, remove the unload tray from the platesetter.
  2. Shut down the platesetter.
  3. Check the top rear cover.
  4. Check the top front cover.
  5. Check the left side door.
  6. Check the unload panel.

Technical contact(s)
 

Content owner: Nir Peleg
See the Escalation page for escalation contacts.

Date submitted
 

16 Jan 2006


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.