Background
|
|
The objective of performing a delay test is to calibrate the delay parameter
for the Data Distribution Board (DDB), so that the exposed horizontal
lines are perfectly straight. The plate is exposed at a resolution of
100 dpm, in different delay values. The optimal delay value is the delay
value of the best exposure. ThermoFlex Controller automatically calculates
the optimal delay values for other resolutions.
Note: Test results do not depend on the plate type or size, so
this test can be performed on any plate type that the customer uses.
Note: When defining media, if you do not enter the correct media
thickness, delay problems will appear on the actual job.
|
Procedure
|
|
This procedure contains two stages:
Testing delay
- Load a test plate.
- Load a plate.
- In TIFF FE, from the Launch Pad, select Utilities > Calibrate.

- In the Calibration Type box, select Delay.

- In the Current Plate list, select the Plate that you are using.
- Select the relevant test file according to the type of plate:
- Flexoselect machineCalibTest.lw
- Offsetselect CalibTest100AM.K.TIF
- Offset Staccatoselect CalibTest100FM.K.TIF

Note: If your plate type is Flexo, you must also select the relevant
screenset. For example:

- Define the Image offset values:
- Horizontal offsetThe value around the drum in mm
- Vertical offsetThe value along the drum in mm
If you use the same plate for several tests, define different offset
values for each test.
Note: The (0,0) offset coordinate is located at the upper-left
corner of the plate.
- In the Test Delay Value area, type the values for the delay
range.
For coarse delay calibration, the recommended range is:
- For Flexo plates using a 1:2 lens: 122126
- For Flexo or Offset plates using a 1:3 lens: 80.584.5

- In the Number of steps list, type the required number of exposures
for the delay range. The recommended number of steps is 11.
- Click Test to initiate the delay test according to the settings.
The application performs several exposures.
- Select the best result and run a fine-tuning test in a range of ±1,
using 11 steps.
Note: After you perform the coarse test, you may need to calibrate
resolution before performing the fine test. Vertical artifacts indicate
that the resolution motor step is out of range.
- Select the best results and run the test in a range of ±0.1,
using 11 steps.
- Repeat step 12 in a range of ±0.05.
Selecting the correct delay
- Develop the plate.
- In the section of the test file shown following, examine the results
with a microscope . A bad delay value results in a jagged effect on the horizontal
line.
-
Broken, uneven lines indicate a delay problem.
-
Smooth, even lines indicate correct delay.
- In the Delay Value box, type the optimal delay value.
- Click Save. The optimal delay value is transfered to Lotem
Controller. Lotem Controller automatically calculates the optimal delay
values for other resolutions.
|