This procedure includes the following sections:
Calibrating drum speed
- Load a plate.
- From the Kodak Xpo palette, select Tools >
Calibration. The Plate Sensitivity parameters of the loaded
plate are automatically transferred from the Lotem/Magnus 400 Controller
software.
- In the Calibrate dialog box, perform the following steps:
- In the Calibration Type list, select DrumSpeed.
- In the Intensity field, the last-saved intensity test value
appears. Type a new intensity value according to the plate that
you are using for the testfor example, 280 for positive (blue)
plates, and a value between 160 to 170 for negative (green) plates.
- In the Drum Speed field, the last-saved drum speed test
value appears. Do not change this value until the optimal
drum speed has been determined.
Note: Accelerated drum speeds require higher intensities
than reduced/low drum speeds.
- Clear the Calculate All Points When Saving check box. This
ensures that the working conditions are updated only for the resolution
that is currently defined.
- In the Test Drum Speed Values [rpm] area, in the From
and To fields, type the test range for the drum speed motor
values. For best results, enter a range that is ±50 motor
steps of the currently displayed motor valuefor example, between
900 to 1300.
- In the Number of Steps list, select the number of exposures
to perform for the selected test focus value range. For best results,
enter a minimum of 10 or 11 steps.
When you type a step value, the Lotem/Magnus 400 Controller software
automatically calculates and displays the size of each step interval
in the Size field, using the following formula:
Step size = (ToFrom)/(Number of steps 1)
Note: The interval value provides a quick reference for the
platesetter operator, and cannot be changed.
- In the Resoluton list, select the resolution used by the
customer.
- In the Test File list, select the TIF file that you want
to use for the drum speed test.
Note: Test files are predefined; the ones that appear in
the list are according to the selected resolution and plate type.
- In the Current Plate list, select the plate that you are
using for the test.
- In the Image Offset fields, type a value in millimeters
for the horizontal offset (around the drum), and the vertical offset
(along the drum).
Note: The (0,0) offset coordinate is located at the upper-left
corner of the plate.
If you use the same plate for multiple tests, enter the appropriate
offset values for each test.
- In the Plate Policy section, select or clear the Load
and Unload check boxes that apply to focus test:
- Load: Automatically loads a new plate before the test
begins. To perform multiple calibration tests on the same plate,
before you start the next test, clear this check box to reuse
the plate.
- Unload: Automatically unloads the plate after the test.
To perform multiple calibration tests on the same plate, before
you start the next test, clear this check box.
- Click Test to start the drum speed test.
Lotem/Magnus 400 Controller performs a series of exposures on the plate,
after which you need to process the plate and examine the results.
Selecting the optimal drum speed
- Visually examine the results, and select the target strip for which
the 50% dot area measures 50%.
Measure the density in the solid area. A good density reading should
be 0.07 dmin or less.
- In the Drum Speed field, type the optimal drum speed value
returned, and click Save.
- Verify that the new value was saved in the database.
- In the Lotem/Magnus 400 Controller software, go to DataBase,
and double-click Res Int.

- In the Resolution/Intensity Tables dialog box, locate the row
with the resolution and laser intensity that was used for the test
and, in the Drum Speed column, the newly-saved value should
appear.
- Click Close.
- If required, repeat the test for other resolutions used by the customer.
|