Thermal2 Parameter
sys laserenable

Description Specifies whether the write laser is enabled or disabled.

If the write laser is enabled ( this NVS parameter is true ), the exposure head will attempt to execute the write laser and stroke calibration commands. This configuration is the default.

If the write laser is disabled ( this NVS parameter is false ), the exposure head will ignore the write laser and stroke calibration commands ( the stroke calibration commands must be ignored since the write laser is disabled ). Note that this configuration is intended only for debugging and / or development purposes.

Note that either the NVS parameter sys plotenable, the NVS parameter sys laserenable or the NVS parameter sys ignorelaser will disable the write laser and stroke calibration.

Type Boolean

Default Value True

Related Documents COMMAND: laser (on|off)
COMMAND: stroke cal
COMMAND: sys laser [on|off]
COMMAND: sys stroke cal
PARAMETER: sys plotenable
PARAMETER: sys ignorelaser
PARAMETER: sys powermode
PARAMETER: sys powermonitor
PARAMETER: sys powerloop
PARAMETER: sys lasercurrent

Applies to: THERMAL2
Access: FIELD
Modified: Mon Aug 27 10:34:57 2007
Updated: Thu Jul 17 02:31:39 2008
Module: SYS