| Description | Specifies whether the exposure head will monitor the write laser power before plotting ( and after turning on the write laser ). | |
| If the write laser power monitor is enabled ( this NVS parameter is true ), the exposure head will monitor the write laser power before plotting. After setting the write laser power using the beam-balance sensor, the exposure head will maintain a constant laser power before plotting. The exposure head maintains a constant laser power by adjusting the laser current to maintain the laser power calculated using the beam-balance sensor. | ||
| If the write laser power monitor is disabled ( this NVS parameter is false ), the exposure head will not monitor the write laser power before plotting. After setting the write laser power using the beam-balance sensor, the exposure head will maintain a constant write laser current before plotting. | ||
| Type | Boolean | |
| Default Value | True | |
| Related Documents |
COMMAND: ldd mode (calibrate|monitor|power|retrace|suspend|current|simulate|reset|_standby|off) [<setpoint>] | |
|
COMMAND: laser (on|off) | ||
|
COMMAND: sys laser [on|off] | ||
|
PARAMETER: sys plotenable | ||
|
PARAMETER: sys laserenable | ||
|
PARAMETER: sys ignorelaser | ||
|
PARAMETER: sys powermode | ||
|
PARAMETER: sys powerloop | ||
|
PARAMETER: sys lasercurrent | ||