Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 3 Errorcode: [07618] Internal balance error exceeds the maximum error

Error details

Thermal3 Errorcode: [07618] Internal balance error exceeds the maximum error
Thermal3 Errorcode
[07618] Internal balance error exceeds the maximum error

Service Information The internal balance attempts to set the pixel level for all pixel quads in the stroke such that the stroke profile matches the target profile within the error configured by the NVS parameter ibs maximumerror. This error indicates that six fine balance iterations were not able to achieve a stroke profile that matches the target profile.

Enabling the verbose information for the internal beam-balance sensor subsystem will display the results of the coarse balance and six fine balance iterations. This information will include the pixel level and errors for the final fine balance iteration.

Typically the internal balance will succeed if the NVS parameter ibs maximumerror is increased or the NVS parameters med <media index> beamslope <polarity>, med <media index> beamcurve <polarity> or med <media index> beampiston are decreased.

Operator Action Call service.

Causes
  • The internal balance could not achieve a stroke profile that matches the target profile.

Related Documents COMMAND: ibs balance [nocal]
COMMAND: vbs enable (<subsystem>|all) <level>
PARAMETER: ibs maximumerror
PARAMETER: med <media index> beamslope <polarity>
PARAMETER: med <media index> beamcurve <polarity>
PARAMETER: med <media index> beampiston
PARAMETER: med <media index> stroke <polarity / spot quad>
PARAMETER: med <media index> scorr <polarity / spot quad>

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:34 2008
Updated: Wed Jul 16 04:52:20 2008
Module: IBS