Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 3 Errorcode: [05216] The laser current exceeds the current limits

Error details

Thermal3 Errorcode: [05216] The laser current exceeds the current limits
Thermal3 Errorcode
[05216] The laser current exceeds the current limits

Service Information The monitor commands ldd cal (dual|a|b) <setpoint>, ldd on (dual|a|b) <setpoint>, ldd on man (dual|a|b) <setpoint>, ldd current (dual|a|b) <setpoint> and ldd man (dual|a|b) <setpoint> will set the laser diode control mode. This error indicates that the setpoint will cause the laser current to exceed 120% of the nominal current.

The laser power control loop will maintain the laser power by adjusting the laser current. If the laser current exceeds 120% of the nominal current, a fatal fault will be generated from a single occurence. As a result of the fatal fault, the laser diode driver is shutdown and the system fault handler will shutdown the exposure head. Note that this error code is also returned to the host as an unsolicited fatal fault.

Operator Action Call service.

Causes
  • The requested laser power is too high.
  • The requested laser current is too high.
  • The nominal current of the laser diode is too low.
  • The laser diode is nearing end-of-life.

Related Documents COMMAND: ldd cal (dual|a|b) <setpoint>
COMMAND: ldd on (dual|a|b) <setpoint>
COMMAND: ldd on man (dual|a|b) <setpoint>
COMMAND: ldd current (dual|a|b) <setpoint>
COMMAND: ldd man (dual|a|b) <setpoint>
PARAMETER: ldd nominalcurrenta
PARAMETER: ldd nominalcurrentb

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:35 2008
Updated: Wed Jul 16 04:52:17 2008
Module: LDD

Troubleshooting information

Related Procedure(s)

 