Thermal 3 Errorcode: [05202] The control mode is invalid

Error details

Thermal3 Errorcode: [05202] The control mode is invalid
Thermal3 Errorcode
[05202] The control mode is invalid

Service Information The monitor commands ldd cal (dual|a|b) <setpoint>, ldd on (dual|a|b) <setpoint>, ldd on man (dual|a|b) <setpoint>, ldd current (dual|a|b) <setpoint>, ldd man (dual|a|b) <setpoint>, ldd hold and ldd off will set the laser diode control mode. This error indicates that the laser diode control mode is invalid.

Operator Action Call service.

Causes
  • Firmware error that will occur during firmware development and testing.

Related Documents COMMAND: ldd cal (dual|a|b) <setpoint>
COMMAND: ldd on (dual|a|b) <setpoint>
COMMAND: ldd on man (dual|a|b) <setpoint>
COMMAND: ldd current (dual|a|b) <setpoint>
COMMAND: ldd man (dual|a|b) <setpoint>
COMMAND: ldd hold
COMMAND: ldd off

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:35 2008
Updated: Wed Jul 16 04:52:18 2008
Module: LDD

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.