02 Nov 2006: Connectivity page added More...
A Connectivity page has been added to the site. It includes links to device connectivity pages and information on Kodak connectivity to third-party workflows.
TechPlanet DVD Version 5 N.301 Nov 2006
TechPlanet DVD Version 5 N.201 Jun 2006
23 Feb 2006: Safety Policies document updated More...
The Safety Policies for Service Engineers document has been updated. All service engineers are strongly encouraged to read the updated safety policies and reminded to always apply these policies when working on or around the Kodak output devices.
16 Feb 2006: Creo Feature Licensing (CFL) information More...
A site about Creo Feature Licensing (CFL) replaces the Creo Feature Licensing page. Click Feature Licensing under Related Sites in the side menu to access the CFL site.
TechPlanet DVD Version 5 N.1 and Mature Products 200631 Jan 2006
TechPlanet DVD Version 4 N.330 Sep 2005
15 Jul 2005: Troubleshooting: Drum oscillation on MCE output devices More...
A new troubleshooting item is available on the Troubleshooting page, describing a set of circumstances that can cause drum oscillation when there is nothing wrong with the drum amplifier. Specifically, if a drum stop command is the first command issued after the output device has been reset or the safety loop has been broken and closed, the drum will oscillate. (The oscillation is worse when the drum stop command is immediately followed by a drum move command.)
This problem exists in DRS firmware earlier than version 2.34. It is solved in DRS version 2.34, but at this time, no firmware releases yet contain this version. In the meantime, it is important to be aware that drum oscillation does not necessarily mean there is a problem of any kind with the output devices hardware components.
11 Jul 2005: Escalation contact information for CAP updated More...
CSC-PSS contact information for CAP has changed. A new e-mail address and separate phone numbers for Australia and Shanghai are now available.
The following Escalation pages have been updated:
The following Escalation pages will soon be updated:
Click the contacts link on the Escalation page.
21 Jun 2005: Translations of installation test procedure checklists available More...
Dutch, French, German, Italian, and Spanish translations of the installation test procedure checklists are posted on the Installation pages for Trendsetter 400/800 II base, AL, CL, and Spectrum, Trendsetter NEWS, Magnus VLF and AL, and VLF Trendsetter and AL. Click the ITP link on the Installation page.
03 Jun 2005: Magnus VLF and TH3 serial numbers More...
Serial numbers for the Magnus VLF and TH3 have been posted on the Machine Serial Numbers page.
TechPlanet DVD Version 4 N.231 May 2005
12 May 2005: Universal sensor tester improved More...
The universal sensor tester (part number 90-1112B) has been improved to be more versatile. The user guide has also been updated. Information is posted on the Tools page.
11 May 2005: Encoder cleaning procedure updated More...
The cleaning kits for optical (glass) encoders have been updated and the cleaning fluid replaced with a generic glass cleaner. See the link under Encoder on the Procedures page for the device.
20 Apr 2005: Link to Installation Feedback Report form added More...
See the link under Installation Procedures on the Installation page for the device. Be sure to send an Installation Feedback Report after completing a device installation.
TechPlanet DVD Version 4 N.1 and Mature Products 200531 Jan 2005
20 Dec 2004: Time estimates removed from PM Checklists for customers More...
Click the Maintenance page for the device for revised checklists (including translations) and for details on how to complete the checklist online.
02 Dec 2004: Translations of MSDS for pink (82-1032A) and blue (402-00056) chiller coolant available More...
Click the Chiller MSDS link on the safety page.
20 Oct 2004: The All CTP Devices site now includes information about Lotem 800 platesetters More...
The ALL CTP site has been updated and now contains information about Lotem 800 platesetters.
TechPlanet CD Version 3 N.330 Sep 2004
30 Aug 2004: Safety Procedures for Service Engineers More...
You must follow Safety Policies for Service Engineers posted on the Safety page to protect yourself, your co-workers and customers.
18 Aug 2004: Checking GENINE board installation More...
When installing the GENINE board, the plastic film MUST be removed from the heat sinking compound on the back of the board. Failure to remove this film can lead to unexpected resets or premature failure of this board. For devices built between 1 April 2004 and 20 July 2004, please verify that the GENINE board has been installed correctly. See Checking GENINE board installation on the Procedures page
TechPlanet CD Version 3 N.214 Jun 2004
09 Jun 2004: Polyscience Chiller error Fixed More...
The troubleshooting note dated April 01, 2004 reported problems with control over the external chiller due to a wiring error in the interface. This error has been corrected by Polyscience and is not longer an issue.
The faulty interface resulted in a detect error on the chiller cable. Most of the chillers have been modified in-house, but if you still see this error or if you notice that the cable detect is masked, refer to the troubleshooting note or contact Al Edge for instructions on how to correct the problem.
12 Apr 2004: Controlled releases for all devices at a glance More...
All controlled releases are listed in a table on the Control/Settings page, along with their date of release. Bookmark this page if you often need to find controlled releases for multiple products.
08 Apr 2004: Firmware Upgrades: Backing Up and Restoring MCE/MPE Boards document revised More...
Instructions on upgrading Lionel board firmware on the ThermoFlex Wide II device, the UDRC-L unit, and the Magnus VLF device have been added to Firmware Upgrades: Backing up and restoring MCE, MPE, PDB, LIONEL, and GENINE boards. The revised document is posted on the Procedures and Control/Settings pages.
01 Apr 2004: Problems with control over the external chiller More...
On the recent version of the PolyScience chiller, which is a grey model rather than black, there is an error in the interface connector on the back. The interface has a cable detect that signals the device firmware to turn the coolant pump and the compressor on/off, but some chillers have the incorrect interface installed. See the Chiller Troubleshooting page for a workaround that will fix the cable detect and give some control over the chiller. A field change order (FCO) will be issued later to provide a permanent fix.
TechPlanet CD Version 3 N.129 Feb 2004
25 Sep 2003: MOVs and spark gaps are being removed from devices (ECO CA01804) More...
Creo MPE devices are no longer being shipped with metal oxide varistors (MOVs) and spark gaps between line and ground. The MOV assembly should be removed from units in the field at the next PM visit. See each output device's FCOs page for details.
TechPlanet CD Version 2 N.3/415 Sep 2003
15 Sep 2003: Problem With Backing Up NVS Parameters When Using Service Shell v2.4 SP1 More...
The installer file for Service Shell v2.4 SP1 is generating an error message when NVS parameters are backed up. The message will read:
24 Jul 2003: Cleaning Kit for the Final Window More...
It is important to ensure that the final window is clean before swapping out a head because debris build-up can cause a serious reduction in both image quality and power output from the head. A high percentage of heads returned with image quality issues have not had the final window cleaned, and this costs Creo unnecessary money.
A new window/lens cleaning kit (Lens cleaning kit: 04-0012B BOM) is now available that will make lens cleaning easier. It includes:
Ordering tip: Because of the relatively high cost of shipping this kit, it is most cost-effective to order the kit in multiples of three.
Refer to the Lens Cleaning FAQ for more information.
TechPlanet CD Version 2 N.228 Apr 2003
23 Apr 2003: MPE to MCE: Two new documents have been posted More...
The following documents have been posted to the MCE Info page:
14 Apr 2003: How to find controlled releases and test files More...
Reminder: Use this All CTP site as a tool to find your way to information that is in Trendsetter product sites on TechPlanet. For example, all the controlled releases and test files are listed in the hot links above. Or use the Quick Index to find other elusive documents.
28 Mar 2003: Trendsetter MCE Information Page More...
This page contains information that is specific to Trendsetter MCE devices. Note that the terms Type II, TSM, and MCE are all used to refer to Trendsetter MCE in Trendsetter documentation.
All of the information listed on Trendsetter MCE Info is also available on the relevant pages within the Trendsetter 400/800, Trendsetter AL and Trendsetter NEWS sites.
17 Mar 2003: All CTP Devices site updated with MCE info More...
This site has been updated to include links for MCE information. Currently the Trendsetter 400/800, Trendsetter 400/800 Autoloader, and Trendsetter NEWS devices in production use MCE.
14 Mar 2003: Diagnosing pneumatic cylinder problems More...
When a pneumatic cylinder does not push or pull properly, it should be checked for damage and for leaking air. Methods for troubleshooting cylinders and testing for air leaks are given in Diagnosing pneumatic cylinder problems.
05 Feb 2003: Most Trendsetter devices now ship with debris removal More...
All Trendsetter devices (MPE and MCE) are now shipped with a UDRC for debris removal, except for Trendsetter NEWS and Proofsetter Spectrum. See the Debris Removal site for more information about the UDRC.
TechPlanet CD Version 2 N.124 Jan 2003
05 Dec 2002: Missing a partial swath More...
On VLF devices that have a 1.x thermal head, an error has been reported where part of a swath is missing on the plate, and a full swath may also be missing. This occurs randomly during a plot and may require replacement of the LC-BP and the coaxial (hotlink) cables. For details of the problem, see Missing a Partial Swath.
06 Nov 2002: Air compressors for Creo output devices More...
Creo output devices require clean, dry compressed air. An internal white paper offers general guidelines for achieving the specifications for air cleanliness, volume and pressure as outlined in the Site Preparation & Requirements document for each device. See the Installation page for the link, or go directly to Air Compressors for Kodak Output Devices.
TechPlanet CD Version 1 N.426 Oct 2002
24 Oct 2002: Replacement cables and sensors for load ramps, load tables, and unload pans More...
Fretting on contacts between cable and sensor was causing loss of connection. A new cable and sensor should be installed for improved reliability. See E897 on device FCO page for appropriate kit numbers and procedure.
10 Oct 2002: How to find differences between NVS dump files More...
A very quick and thorough method to find differences between two text files is to use the WinDiff utility. The WinDiff tool graphically displays the differences between two ASCII text files, and is particularly useful for comparing NVS dump files. It is available on the Tools page.
08 Oct 2002: Maintenance link back on side menu More...
At the request of many TechPlanet users, we have added Maintenance to the side menu on output device websites. The Maintenance link opens a page that contains the documents and scheduling needed to perform effective PMs.
23 Jul 2002: Longer cable and hose for UDRC-B (ECO E921)More...
Some customers find the UDRC too noisy. The UDRC kit now includes longer hoses and cables so that the unit can be placed farther away from the device operator. See the attachment kits (11-1068B and 11-1069B) on the UDRC Parts page for information.
TechPlanet CD Version 1 N.2/312 Jul 2002
15 Jul 2002: Unimaged strip seen on positive plates after an MPE firmware upgrade More...
At sites where customers use positive plates, avoid a firmware upgrade unless it is absolutely necessary. An artifact has been seen lately on Trendsetter VLFs and Trendsetter Spectrums, and it is suspected that it affects all MPE-based devices. The artifact is an unimaged strip, 0.5 to 1.0 mm wide, visible on positive plates at the away end of the plate. The solution to the problem is to downgrade to an earlier version of the MPE firmware.
If you must do a firmware upgrade because you are replacing a thermal head, or for some other reason, see the troubleshooting note for tests to verify that the plates will be free of the problem and for a possible workaround if the problem does occur.
27 Jun 2002: Controlled releases launched More...
A controlled release is a package of software components that are compatible with each other and with the hardware of a specific output device configuration. These packages are tested by Product Development and then released under an ECO to ensure version control.
It is no longer recommended to simply download the latest version of firmware or software. Rather, upgrade all components to a controlled release version. The controlled release documentation will identify the dependencies and workflow system compatibility. In some cases upgrading only one component may be appropriate, but it should be an exception.
Controlled release CDs are now being shipped with each new output device, and packages will be sent out quarterly to the regions for field upgrades. For more information about controlled releases, follow the links for any device on the Control-Settings page.
05 Jun 2002: Laser Safety Bulletin More...
Please read the Laser Safety Bulletin for Trendsetters to be reminded of the possible dangers of working with an active laser. This bulletin also explains the correct use of the safety interlock override (SIO) keyswitch.
03 Jun 2002: Machine serial numbers More...
Creo's Response Center has compiled a quick reference guide to the serial numbers for Trendsetter and Platesetter devices, and it has been reproduced here for field service. See the Parts page for a link to the serial numbers page.
03 May 2002: Power & Environmental Site Surveys More...
Creo has a contract with Rx Monitoring Services in Manchester, NH (603-666-6606 ext201) to provide Power & Environmental Site Surveys for the NAFTA region. The monitoring service includes voltage, current, temperature, humidity, dust and air pressure. Rx will provide the equipment to be installed at the customer site (for a maximum of 10 days), monitor it and send an e-mail report.
Air pressure monitoring is the latest addition to the Power & Environmental Site Survey. See Installing the Rx Air Pressure Sensor for details.
10 Apr 2002: Pneumatic Hoses and Fittings More...
Creo's Response Center has compiled a quick reference guide to pneumatic hoses and fittings, organizing the hoses by dimensions and the fittings by type. Part numbers, descriptions, dimensions, item numbers and references to drawings are provided. See the Parts page for a link to the hoses/fittings page.