Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Applies to |
|
|---|
Machines affected |
All |
|---|
Component |
Carriage |
|---|
Problem |
There are dependencies in the firmware between the carriage, head, drum and encoder. HDM and HDP parameters are stored in the head, so if head communications are lost after powering up, the firmware may get confused. |
|---|
Symptoms |
The head loses communication with the MPE board, and then the carriage stalls. |
|---|
Solution |
If head communications are not working, set "sys hi" (head installed) to 0. |
|---|
See also |
Other carriage troubleshooting procedures: |
|---|
Technical contact |
David Lamont |
|---|---|
Date submitted |
December 22, 1999 |