Lotem 800 Installation Guide
Lotem 800 Calibration

Previous Page  ToC  Next Page

Focus Test
Elevation test
Intensity Test
Resolution Test
Delay Test
Excurve/Res Intensity/Tone Reproduction Test

This chapter describes the calibration procedure of the optic system of the Lotem 800. This procedure is performed by the service engineer at the customer's site, after the platesetter installation.


Important note !

After installation, there is no need to calibrate the machine. You should expose the SDT file from the Brisque and examine the plate. If results are unsatisfactory, perform the following calibration tests.


Note: The results for some of the calibration tests depend on the plate type; these tests should be repeated for different plate types.

The calibration tests and the setting of the optimal values are performed from the Brisque, using the Lotem 800 calibration application. All machine calibration parameters are then saved on the PC controller.

Calibration objectives:

  1. To find the optimal focus stepper motor value for different plate types.
  2. To determine the optimal drum speed and laser intensity for a given plate for resolution of 100.
  3. To find the optimal beams delay.
  4. To calibrate the resolution motor for five (5) main resolution values (60, 80, 100, 120,140)
  5. To determine the optimal angle of elevation of the optical head.

Copyright (c)1998 Scitex Corporation Ltd. All rights reserved. Certain names, logos, designs, titles, words or phrases on this page may constitute trademarks, servicemarks, or tradenames of CreoScitex Corporation Ltd. or other entities which may be registered in certain jurisdictions.