Product

 
  • Kodak® ThermoFlex® Mid
  • ThermoFlex Narrow

Background

 

Since each customer works with different screening, the calibration tests results may not be sufficient for flexo plates and you must perform final calibration.

The usual test files, listed following, are very large and only a small section (no more than 5 cm) is required. Use TIFF Assembler to crop the section that you need.

Test file Resolution Recommended cropping
Diode test
2400
Crop mesh 150 and 175 lpi
ITP 2400/2540 Crop section containing vignette
Customer file varies Crop area containing both screen and solid, and vignette if one exists
 

Requirements

 

Note: For devices with a magnetic drum, use a plate of the same type that does not have the steel back. This type of plate is provided by the plate manufacturer for calibration purposes. If such a plate is not available, you will need to develop the plate to check for image quality.


Procedure

 
  1. In the Hardware Tree, in the Database folder, open the Laser Info table.
  2. Expose the cropped file ten times, with a different DDB factor each time, according to the following table:

    Diodes
    48/24
    DDB factor per test
    1 2 3 4 5 6 7 8 9 10
    0
    0 10 10   10 10   10 10  
    1
    0 7 7         5 5  
    2
    0 4 4              
    45/21
    0 4   4            
    46/22
    0 7   7       5   5
    47/23
    0 10   10 10   10 10   10
  3. Select the best results: the results with no slashes, patterns, or other artifacts.
  4. If none of the results are perfect, browse to Xpose\Version\plt_calib\files and save the cropped file in the files folder.
    Note: The Xpose folder may or may not be on the C drive.
  5. Perform a resuolution test, exposing the cropped file, which appears in the list. Use a range of ±15 of the current resolution, in 7 steps (each step increases by 5 microns).
  6. Select the best result.
  7. In the database, in the Res Table, enter the res motor step.