Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Setting up the Magnus 800 platesetter and the Magnus 400 Quantum platesetter for lenticular printing


Product

 
  • Kodak® Magnus™ 800 platesetter
  • Kodak Magnus 400 Quantum platesetter

Background

 

This procedure describes how to set up the Magnus 800 platesetter and Magnus 400 Quantum platesetter for lenticular printing.

Before beginning this procedure, read the Lenticular printing reference guide in its entirety.


Procedure

 
  1. Back up the platesetter parameters:
  2. Use the firmware upload script to install new MCE main firmware and overwriting pattern firmware.
    Note: The overwriting pattern reduces the throughput of the Magnus platesetters by 50%.

    Device Prerequisites Upload Firmware
    Magnus 800 platesetter Magnus 800 Controller software version 1.05 Main firmware version 1.08.07

    Overwriting pattern firmware
    Magnus 400 Quantum platesetter Magnus 400 Quantum Controller software version 1.04.393.001 Main firmware version 1.40.02

    Overwriting pattern firmware

  3. Edit and apply a pattern ID #3 to the media set that is designated for lenticular printing.
    Important: The specific media set should be used only if jittering appears on the exposed plate.
    To edit the media slot and apply the pattern ID, type the following at the Magnus/Quantum command prompts:
    • >> prm hazardous media enable
    • >> set media x patternid 3
  4. Lenticular printing requires a fine tilt adjustment which must not be greater than 1.5 micrometers or 1/6 of a pixel.
  5. Verify the relevant thermal head settings:

Technical contact
 

Content owner: Nir Peleg
See the Escalation page for escalation contacts.