Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Description | Commands | NVS parameters | Parts | Procedures | Theory of Operation
The drum holds the media during imaging.
Diameter: 432 mm (17")
Length between flanges: 2122 mm (83.5")
Weight: 380 lb
chkfly (check_flyoff)
dgh (deriv_gain_hall)
dgp (deriv_gain_posn)
dgr (deriv_gain_posn)
dgs (deriv_gain_run)
dgv (deriv_gain_vel)
diam (nominal_diameter)
epos (edge_position)
gear (drum_gear_ratio)
hppr (hall_pulses_per_rot)
igh (integ_gain_hall)
igp (integ_gain_posn)
igr (integ_gain_run )
igs (integ_gain_soft)
igv (integ_gain_vel)
iner (drum_inertia)
maxdiff (max_hall_vs_enc_diff )
mtcn (motor_torque_const)
mtol (move_tolerance)
pacc (position_accel)
pgh (prop_gain_hall)
pgp (prop_gain_posn)
pgr (prop_gain_run)
pgs (prop_gain_soft)
pgv (prop_gain_vel)
vacc (velocity_accel)
The main components are:
ThermoFlex procedures page: Drum
Removing media from the drum. See the ThermoFlex Wide I Operator Guide - English for the procedure.
The servo loop controls the drum speed. The encoder senses the position and speed and sends the signals to the digital controller on the MPE. The output from the controller is sent out to the MDA which converts the requested drive information into drive current for the motor. The programmed speed and the PID coefficients are stored in the DRUM NVS module.
There are five different sets of PID coefficients for the servo: