Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
This page contains links to VLF Autoloader specific boards. Boards are not
field repairable and therefore no BOMs are provided. Contact your local Response
Center to order the latest revision of boards available.
For boards in the base Trendsetter VLF, see the VLF
Trendsetter boards page.
Warning:
Many of the electrical components in a Trendsetter VLF AL are extremely
sensitive to electrostatic discharges. You must be well grounded with an
antistatic wrist strap connected to a ground point within the Trendsetter VLF AL
before accessing an electrical component.
Some boards and cables in the Trendsetter VLF AL carry hazardous voltage signals. Make sure that you know whether or not a board or cable is carrying hazardous voltage before disconnecting the cable or servicing the board.
L-Conveyor
Multiple Cassette Unit (MCU)
Picker
Power Box
Rotating Conveyor
Single Cassette Unit (SCU)
Straight Conveyor
Trendsetter
Genine
Power Distribution Board (PDB)
Master Processor Electronics (MPE)
| Item | Stored Service Parts | Reference Diagrams | Notes |
|---|---|---|---|
| Genine
(board 34) |
10-4227D | Block Diagram
Connector Pins Schematic |
Upgrade kit - 05-0224 BOM
(ECO E229) |
| Carriage drive board | 503C01525B | Schematic | Replace with 512-00038A. See FCO CA00433. |
| Carriage drive board (inactive) | 10-3761 | Schematic | Replaced May 2003 by 503C01525B. |
| Processor interface / External device interface (EDI) board | 10-4961A | Schematic | Released under ECO E260 as an option. |
| Item | Stored Service Parts | Reference Diagrams | Notes |
|---|---|---|---|
| Operator interface | 10-1420 | ||
| Genine
(board 31) |
10-4227D | Block Diagram
Connector Pins Schematic |
Upgrade kit - 05-0224 BOM
(ECO E229) |
| Carriage drive board | 503C01525B | Schematic | Replace with 512-00047A. See FCO CA00433.
For machines B20 and before that do not have the umbilical cable, order 512-00053A instead of 512-00047A. |
| Carriage drive board (inactive) | 10-3761 | Schematic | Replaced May 2003 by 503C01525B. |
| Safety interface board | 10-4697C | Schematic | |
| Manifold interface | 10-4727A | DWG
Schematic |
| Item | Stored Service Parts | Reference Diagrams | Notes |
|---|---|---|---|
| Genine
(board 32) |
10-4227D | Block Diagram
Connector Pins Schematic |
Calibrate pressure transducers after replacing a picker genine board.
See Procedures page for details. Upgrade kit - 05-0224 BOM See ECO E229. |
| Picker lights | 10-4523 | DWG
Schematic |
|
| Vacuum sensor board
PSEB - pressure sensor expansion board) |
10-4581A | Schematic | ss picker |
| Manifold interface | 10-4727A | DWG
Schematic |
|
| Picker pressure sense board | 10-4887A | DWG | |
| Carriage drive board | 503C01525B | Schematic | Replace with 512-00038A. See FCO CA00433. |
| Carriage drive board (inactive) | 10-3761 | Schematic | Replaced May 2003 by 503C01525B. |
| MPE E-series board, 2MB | 503-00075A | needed for DM picker |
| Item | Stored Service Parts | Reference Diagrams | Notes |
|---|---|---|---|
| Genine
(board 30) |
10-4227D | Block Diagram
Connector Pins Schematic |
Controls the Y-axis. |
| Power Distribution Board
(board 10) |
10-4112H | Block Diagram
Schematic |
Details |
| Master Processor Electronics | 10-3692 |
| Item | Stored Service Parts | Reference Diagrams | Notes |
|---|---|---|---|
| Genine
(board 34) |
10-4227D | Block Diagram
Connector Pins Schematic |
Upgrade kit - 05-0224 BOM
(ECO E229) |
| Carriage drive board | 503C01525B | Schematic | Replace with 512-00038A. See FCO CA00433. |
| Carriage drive board (inactive) | 10-3761 | Schematic | Replaced May 2003 by 503C01525B. |
| Process interface / External device interface (EDI) board | 10-4961A | Schematic |
| Item | Stored Service Parts | Reference Diagrams | Notes |
|---|---|---|---|
| Genine
(board 31) |
10-4227D | Block Diagram
Connector Pins Schematic |
Upgrade kit - 05-0224 BOM
(ECO E229) |
| Carriage drive board | 503C01525B | Schematic | Replace with 512-00047A. See FCO CA00433.
For machines B20 and before that do not have the umbilical cable, order 512-00053A instead of 512-00047A. |
| Carriage drive board (inactive) | 10-3761 | Schematic | Replaced May 2003 by 503C01525B. |
| Item | Stored Service Parts | Reference Diagrams | Notes |
|---|---|---|---|
| Genine
(board 34) |
10-4227D | Block Diagram
Connector Pins Schematic |
Upgrade kit - 05-0224 BOM
(ECO E229) |
| Processor interface / External device interface (EDI) board | 10-4961A | Schematic | Released under ECO E260 as an option. |
| Item | Stored Service Parts | Reference Diagrams | Notes |
|---|---|---|---|
| Relay Delay Control Board | 10-4827A | Schematic | Emergency stop switch control |
Board 10 on the Trendsetter VLF AL is the PDB board - located in the power box. It controls safe voltages, the safety loop, and the cassette blower.
Connector J14 on the 10-4112G and earlier PDBs are 10-pin, whereas J14 on the 10-4112H and later are 16-pin. Use adapter cable 220-00316A when replacing
the PDB with a version H or later board.
If the adapter cable is not available, or as an interim solution, the 10-pin plug can be connected to the top 10 pins of J14, pins 1
through 10 (the 16-pin connector is backwards compatible with the 10-pin plug in older devices). The bottom 6 pins are left empty
(these new pins are used for board addressing in other products). The shape of the pins on the connector ensures that the plug will only
fit into pins 1-10. Take note that the strain relief clip on the side of the connector will be offset so the strain relief will not clip
together when the 10-pin plug is inserted into the 16-pin socket.
10-3692
For details of the MPE board, see the VLF Trendsetter MPE page.
For the procedure to upgrade to a new version of firmware for the VLF Trendsetter AL, see Trendsetter VLF AL Operator Training Checklist.