Resolving imaging problems on ThermoFlex Mid and Narrow


Product

 
  • ThermoFlex® Mid
  • ThermoFlex Narrow

Symptoms

 

Imaging problems


Cause

 

The following are possible causes:

  • Screen problems
  • Improper calibration
  • Faulty diodes

Solution

 

Follow the diagram to resolve imaging problems.
Links to the procedures mentioned in the diagram appear following the diagram.

   
ITP does not succeed:      ITP succeeds:
  • Move the resolution motor ±10 steps
  • Add DDB factors of 10, 7, and 4 to the first three and last three diodes (0,1,2 and 45, 46,47).
 
Technical contact(s)
 

Viki Arviv