Installing the Rx Air Pressure Sensor
On-Site Compressed Air Qualification for Creo Output Devices 73-3624
Firmware Upgrades: Backing up and restoring MCE, MPE, PDB, LIONEL, and GENINE boards
Checking GENINE board installation
Ensuring that the Carriage Driver Board Fan Is Mounted Correctly
Interpreting MCE Sensor I/O Bit States
Replacing a GMCE board
Adjusting and replacing the carriage drive belt
Cleaning the drum and carriage drive pulley
Corrective procedure for loose carriage flex-tube setscrew
Ensuring that the Carriage Driver Board Fan Is Mounted Correctly
Lubricating the Carriage Tracks and Leadscrew
Carriage driver board cooling fan
Ensuring that the Carriage Driver Board Fan Is Mounted Correctly
Chiller
Neslab CFT33D Chiller Installation and Operation
PolyScience Model 6305P Chiller Installation and Operation
Chiller Page
Lytron heat exchanger (for CRS TS3 and TS3/8 devices)Heat Exchanger
Water pump and motor replacement procedure
Cooling system maintenance
Dehumidifier Unit (DHU) Installation Procedure
Upgrade Kit #05-0244
Adjusting the panel reed switches
Isolating the faulty door sensor
Adjusting the door switches
Isolating a faulty door sensor (TS4,TS8)
Optical Encoder Alignment Procedure
Checking the optical encoder
Optical encoder cleaning procedure
Checking the PLL lights on the MPE
Optical encoder troubleshooting checklist
Checking the Shaft Encoder(TS4,TS8)
Shaft encoder alignment procedure (TS4/TS8)
Checking the PLL Lights on the MPE(TS4,TS8)
Carriage
Drum
Encoder
Flyoff sensor
Leading edge clamps (LECs)
Roller
Trailing edge clamps (TECs)
Measuring engine, picker, and table actuator times and adjusting actuators
Drum
Adjusting the drum drive motor belt tension
Adjusting the drum drive motor belt tension (MCE, toothed belt)
Aligning and tensioning the drum drive V-belt
Replacing the drum drive motor belt
Static balancing of the drum in the field
Cleaning the drum and carriage drive pulley
Cleaning the drum
Main drum drive amplifier
Calibrating the 15-3330 drum ampFlyoff sensor
Adjusting an infrared Plate Flyoff Sensor
Leading edge clamps (LECs)
Adjusting the LEC Gap/Actuator Timing on the 3244 Engine
Adjusting the 3244 backbone actuation timings
Reed switch sensor adjustment procedure
Balancing the Trendsetter 3230(TS4),3244(TS8) backbones
Installing Low Profile LEC Clamps
Measuring engine, picker, and table actuator times and adjusting actuatorsRoller
Adjusting the 3244 drum roller
Adjusting the 3244 backbone actuation timings
Checking the pressure regulators on the 3244/3230 engine
Reed switch sensor adjustment procedure
Balancing the Trendsetter 3230(TS4),3244(TS8) backbones
Measuring engine, picker, and table actuator times and adjusting actuatorsTrailing edge clamps (TECs)
Adjusting the 3244 TEC backbone cylinder rod ends
Checking the pressure regulators on the 3244/3230 engine
Reed switch sensor adjustment procedureAdjusting the 3230(TS4),3244(TS8)TEC backbone cylinder rod ends
Adjusting the 3230(TS4),3244(TS8)TEC park position (ppos)
Balancing the Trendsetter 3230(TS4),3244(TS8) backbones
Measuring engine, picker, and table actuator times and adjusting actuators
Accessing the Trendsetter 3244 fan box
Enabling film imaging on Trendsetter 400/800 II (MCE)
Trendsetter 32XX Film and Static Upgrade Instructions
Trendsetter 3244 Film Upgrade Kit BOM 02-4220B
Plate Loading Position Guide for Trendsetter 400/800 III
Placing Plate Alignment Labels on Trendsetter 400/800 (MCE)
Label placement - Technical bulletin for customers
Label placement - Procedure for field service
Keyswitch upgrade procedure
Accessing the Trendsetter 3244 power box
Accessing the Trendsetter 3244 card cage
Accessing the Trendsetter 3244 backplane
Replacing the main transformer on Trendsetter 3244
Power pack (PS1) upgrade procedure for Trendsetter 3244/3230, Autoloader and Spectrum
set sys hpd is set to 1, use V2.0 settings from the media spreadsheet.set sys hpd is set to 0, use V1.0 settings from the media spreadsheet.For information on upgrade options, see Trendsetter Upgrade Paths and Trendsetter Upgrades.