Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
| FCO # | 100 Label | Description | Priority | Action Required | If Done Looks Like This | |||||||||
| CA09835 Mar 2008 |
23 (TMCE Trendsetter 400/800 base, AL, and CL) 28 (TMCE Trendsetter NEWS) |
Add a safety cover over the drum drive V-belt and pulleys to prevent pinch and entrapment accidents. Applies to TMCE Trendsetter output devices with the drum drive V-belt that were shipped prior to the introduction of the safety cover (serial numbers TM1017 to TM1081 for Trendsetter 400/800 base, AL, and CL, and NM538 to NM588 for Trendsetter NEWS). | Next visit | Install upgrade kit #512-00365A. FCO upgrade procedure Related procedure: Aligning and tensioning the drum drive V-belt |
![]() |
|||||||||
| CA12621 Nov 2007 |
4 (GMCE) | New yellow Propylene Glycol coolant(090-00326A) replaces pink Ethylene Glycol coolant(82-1032A) Applies to serial numbers TG0365 and lower, and NG0262 and lower. |
FYI | Some regions or customers may have HSE regulations that restrict the use of ethylene glycol. Any Trendsetter or Trendsetter NEWS customer that requests HSE-friendly propylene glycol should be upgraded. GMCE devices marked with 100 label #2 have hoses with Viton seals (50-1925E and 50-2450B) installed and are ready to use the new coolant. For other devices, order one of the following upgrade kits: 512-00451A for single head devices Procedure 512-00452A for dual-head devices Procedure |
||||||||||
| CA12332 May 2007 |
3 (GMCE) | Replace the UDRC bulkhead on GMCE Trendsetters with a conductive-coated bulkhead plate to prevent EMC-radiated noise leakage. Applies to serial numbers TG0362 and lower, and NG0261 and lower. | Next visit | Install upgrade kit #512-00442A. UDRC Bulkhead Plate Upgrade Procedure |
||||||||||
| CA10122 25 Aug 2006 |
25 (MCE) | Replace mechanical film guide’s LEC (away side) guide mount. Applies to MCE Trendsetter output devices with the drum drive V-belt (serial numbers TM1018 to TM10163). | Next visit | Install upgrade kit #512-00372A. FCO CA10122: Mechanical Film Guide Mount Upgrade Procedure |
||||||||||
| CA10120 20 Jul 2006 |
24 | New struts for front panel. For serial numbers TM676 to TM1130. These struts cannot be used on Spectrum devices. | Next failure | If the old front panel strut (55-0564) fails, order kit number 512-00368A. This kit is an upgrade from a single strut to a dual-strut design. Dual Strut Upgrade Procedure | ||||||||||
| CA09771 18 Apr 2006 |
N/A | Replace defective chillers with heat exchangers on Trendsetter 3230/3244 (TS3 and TS3/8). For details see the Heat Exchanger page. | Next failure | Replace chiller with heat exchanger. | ||||||||||
| CA08946
Dec 2005 |
Update 1 for Trendsetter 400/800 base, AL, CL, and Spectrum Controlled Release MCE 4.1. This update fixes a flyoff problem for Spectrum devices and reduces the unload table hold current of the traveller motor to prevent the motor from overheating on Autoloader and ContinuousLoad devices. You must have CR 4.1 installed before installing this update. | Next visit | See Trendsetter 400/800 Controlled Release MCE 4.1, Update 1. | |||||||||||
| CA03931 - TS3 and TS3/8
Sep 2005 |
N/A | Change TEC reed or microswitches to optical sensors on
TS3 and TS3/8 MPE devices to improve reliability. The procedure involves replacing
the old TEC backbone with a new TEC backbone. For serial numbers S001-S387
and S983631001-S993631323.
Note: This FCO should only be applied if there have been repeated failures of the TEC backbone, clamp microswitches and/or reed switches. Do not apply this FCO for an individual switch failure. |
Next failure | Order kit 512-00123B.
TEC Optical Sensor Upgrade Procedure (TS3 and TS3/8) Return old TEC backbones for reworking. |
||||||||||
| CA03931 - TS4/TS8 Heidelberg-built devices
Sep 2005 |
22 | Change TEC reed or microswitches to optical sensors on
TS4/TS8 Heidelberg-built devices to improve reliability. The procedure involves replacing
the old TEC backbone with a new TEC backbone. For serial numbers Sxx386xxxx (TS400/800), Sxx371xxxx (TS4), and Sxx385xxxx (TS4).
Note: This FCO should only be applied if there have been repeated failures of the TEC backbone, clamp microswitches and/or reed switches. Do not apply this FCO for an individual switch failure. |
Next failure | Order kit 512-00103C.
TEC backbone optical upgrade for TS4/8 Heidelberg-built devices Return old TEC backbones for reworking. |
||||||||||
| CA07165
May 2005 |
N/A | New, more reliable cooling circulation pump and motor | Next failure | If the old pump fails, replace the pump only. If the old motor fails, replace both motor and pump. Water pump: 510P1P973A Motor: 500-02914A |
||||||||||
| CA06199
May 2005 |
17 (MCE) 21 (NEWS MCE) |
Mean Well power supplies replacing Astec power supplies. Factory installation of these power supplies started at serial number TM736 and NM344. PS4 for NEWS 200 has not changed. |
Next failure | Order kit number 500-02643A for PS1 Procedure 500-02645A for PS2 Procedure 500-02646A for PS3 for TH1.7 and TH2 Procedure 500-02647A for PS3 for NEWS 200 500-02648A for PS4 for TH1.7 Procedure 500-02649A for PS4 for TH2 |
||||||||||
| CA06616
May 2005 |
20 (MCE) 23 (NEWS MCE) no 100 label # for MPE |
More reliable pivot blocks for all Trendsetters Factory installation of these pivot blocks started at serial number TM751 and NM354. |
Next failure | Order kit 512-00260A that contains 2 short and 5 long pivot blocks, 7 screws, and Replacing pivot blocks (CA06616) procedure. | ||||||||||
| CA05160
Sep 2004 |
13 (MCE) | FCO CA00752 introduced a new carriage driver
board (503C01525B), which has a switching power supply that generates a
high level of electrical noise. This noise is fed into the MCE board via
carriage driver board power cable 220-00061A, which can cause SCSI CRC
check errors, digital I/O errors, and low-level firmware errors.
Applies to TM520 and lower |
Next visit | Replace carriage driver board power supply
cable 220-00061A with cable 220-00163B. The new cable connects directly to
the power supply (PS2), so does not feed noise into the MCE board.
See procedure: Replacing the Trendsetter Carriage Driver Board Power Supply Cable (FCO CA05160) |
Carriage driver board power cable goes to PS2, not MCE board connector J13. | |||||||||
| CA04904
Jul 2004 |
12 (MCE) | Wrong pin used for load ramp sensor extension cable (10-5155A) that could cause cable failure. This cable was used in devices with serial numbers TM042 to TM467. | Next visit | Replace with cable 10-5155B. This cable replacement applies to devices with serial numbers TM042 to TM467. | ||||||||||
| CA04411
Jun 2004 |
Update 1 for Trendsetter 400/800 Controlled Release MCE 3.2. This update should only be applied to solve specific UDRC problems on devices that have Trendsetter 400/800 Controlled Release MCE 3.2 installed. | Next failure | See Trendsetter 400/800 Controlled Release MCE 3.2, Update 1. | |||||||||||
| CA03738 - TS8 MPE
Mar 2004 |
22 (MPE) | Change TEC micro-switches to optical sensors on
TS8 MPE devices to improve reliability. The procedure involves replacing
the old TEC backbone with a new TEC backbone. For serial numbers TExxx
(Trendsetter 400/800), PXxxx (Proofsetter).
Note: This FCO should only be applied if there have been repeated failures of the TEC backbone, clamp micro-switches and/or reed switches. Do not apply this FCO for an individual switch failure. |
Next failure | Order kit number 512-00083C.
TEC Optical Sensor Upgrade Procedure (MPE) Return old TEC backbones for reworking. |
||||||||||
| CA03738 - MCE
Mar 2004 |
11 (MCE) | Change TEC micro-switches to optical sensors on MCE devices to improve reliability. Applies to TM327 and lower. | Next PM | Order kit number 512-00081A.
TEC Optical Sensor Upgrade Procedure (TSM) |
||||||||||
| CA02565
Jan 2003 |
n/a | Change drum amp shunt resistor on MCE devices to prevent damage by high surge of current. | Next failure | Order kit number 512-00084A for cable 10-4843B, 512-00087A for cable 10-4842A | ![]() |
|||||||||
| CA00752
Dec 2003 |
n/a | Carriage Driver Upgrade for MPE/MCE to increase
the performance and reliability of Trendsetter carriage systems. The new
carriage driver board operates from a single 48V power supply and does not
need PS3 to operate. This FCO applies to:
|
Next failure | Order kit number 512-00040A.
Carriage Driver Upgrade for MPE/MCE (FCO CA00752)Procedure |
||||||||||
| CA02432
Nov 2003 |
n/a | Controlled Release MCE 3.0 | Next visit | See the Control-Settings page for more information. | ||||||||||
| CA01804
Sep 2003 |
n/a | Remove MOVs and spark gaps between line and
ground.
Replaces B931 |
Next PM | Creo MPE devices are no longer being shipped with metal oxide varistors (MOVs) and spark gaps between line and ground. The MOV assembly should be removed from units in the field (serial numbers TE 799 and earlier) at the next PM visit. Remove the screws and slide out the power entry box (11-0589B). Remove the three MOV assemblies (10-4018A) by loosening the screws on the terminal block. Fasten the power entry box back in place. Mark the 100 label. | ||||||||||
| CA01954
Aug 2003 |
n/a | Controlled Release MCE 2.0 | Next visit | See the Control-Settings page for more information. | ||||||||||
| CA01716
Jul 2003 |
n/a | Pneumatic tubing to prevent possible air leaks near the U74 sensor on 10-4766D-D and earlier MCE boards | Next failure | Order kit number 512-00066. Kit includes fitting and clear pneumatic tube. The fitting connects to the pressure side (top pipe) of the U74 sensor on the MCE board. | ![]() |
|||||||||
| CA01615
Jul 2003 |
n/a | Controlled release MCE 1.2 | Next visit | See the Control-Settings page for more information. | ||||||||||
| CA00663
May 2003 |
3(MCE) | Replacement carriage driver board for MCE devices. 503C01525B replaces 10-4935C | Next failure | Order kit number 512-00041 to replace failed 10-4935C. Kit includes carriage driver board and cables. | ||||||||||
| CA00778
May 2003 |
n/a | Controlled release MPE 1.2 and MCE 1.1 | Next visit | See the Control-Settings page for more information. | ||||||||||
| CA00386
Feb 2003 see Note: |
2 (MCE) | Kit available for UDRC-LC connectivity. | Next visit | Order kit number 512-00043
Note: MCE only |
||||||||||
| CA00398
Jan 2003 see Note: |
3 (MCE) | TEC lock/unlock sensors are getting damaged during operation. New guide will protect sensors from contact with lock/unlock tabs. | Next visit | Install new guide (252-00551A). See detail A in Assembly Drawing.
Kit 512-00022 Note: MCE only |
||||||||||
| E897
Oct 2002 |
31 (TS3) | Plate sensors on load ramp, load table, and unload table lose connection due to fretting on the contacts between the cable and sensor. Replacement high flex cables have more reliable connectors. Sensors must be replaced in case of corrosion caused by previous connectors. | Next failure | See Replacing Sensors and Cables - FCO E897 for kit numbers and device procedure. | ||||||||||
| CA00063
Oct 2002 |
n/a | TEE Board replacement kit includes TEE board plus necessary LUER fittings. | FYI | Order kit number 518-00003 when you have to replace a TEE board. | ||||||||||
| E740
Aug 2002 |
n/a | Processless Debris Removal Upgrade,
TS4/8 Page, UDRC-LC
Note: name changed from Processless to Chemistry-Free (Sep 2002) |
FYI | Kit number 02-4497A-A. See Trendsetter 400/800 Processless Plate Imaging System, UDRC-LC Installation/Upgrade Procedure for information on kit ordering, firmware requirements, and site requirements for UDRC-LC. | ||||||||||
| E921 | n/a | Hose and cable length increased from 3m to 7.6m for UDRC so that unit can be moved farther away to reduce noise. Updated 4/8 Page,Debris Removal Kit,UDRC-B (02-4468A-C) | Next Failure | |||||||||||
| E854 | 18 | Trendsetter 400/800 Controlled Release MPE 1.0 | Next Visit | See Controlled Release 1.0 for details and ordering information. | ||||||||||
| E833 | n/a | Updated 4/8 Page,Debris Removal Kit,UDRC-B | Information only | Kit number 02-4468A-B. See Trendsetter 800/400 Upgrade procedure, particulate ablative media for information on ordering UDRC-B. | ||||||||||
| E492 | n/a | Current drawn by the carriage amp can insufficient to reliably maintain PS3 operation, resulting in a cyclic DC on/off condition. | Next Failure | Add newly created adapter cable 10-5067A in-line with the existing PS3/4-CA cable in the common power box to draw minimum current load from PS3. See FCO E492 procedure. | ||||||||||
| E445
Jan 2002 |
N/A | Improved debris nozzle(50-2117C) is less likely to clog the vacuum sensor port with ablative debris. Click on the photo below for old and new versions of nozzle.![]() |
Next failure | Order kit 05-0246 - includes nozzle, air jet plate, tube and fitting Install procedure |
||||||||||
| E404 | 17 | Common drum (50-2111) used for TS8 and NEWS | Information only | Registration pins for old drums (50-1854) are obsolete. New drums can be identified by crescent-shaped brass counterweight mounted on endbell. Drum requires belt tension of 70Hz. For parts information, see Engine. | Assembly Drawing. | |||||||||
| E243 | #16 | Fanbox | Information only | To see how the latest version of the fanbox affects service, see FCO E243. | See photos in FCO. | |||||||||
| E041 | n/a | Redesign of the top panel to accommodate a new Southco latching mechanism. | Information only | Service needs to order the new hinge when replacing the top panel. For parts information, see Top Panel Kit. | See page 2 of top panel assembly Drawing. | |||||||||
| E453 | n/a | Update to DHU installation kit. | Next Failure | See FCO E453 for kit number and installation procedure | No desiccant box. | |||||||||
| E405 | #15 | Replacement of Morgan cabinet with UDRC-B | Next Failure | See debris removal website for information on parts, maintenance, etc | photo | |||||||||
| E312 | n/a | Load ramp sensor #36-3141 has wrong focal length. Replace with #36-3210. | Next visit | See FCO E312 for information. | n/a | |||||||||
| E114
(May 01) |
#12 (TS8) | Standardized Power Box for all Trendsetter models. High speed drum motor and stepper carriage motor for manual load engine. New SCSI cable. | Production only except for SCSI cable. | Replace SCSI cable. For details,
see FCO_E114.
For parts, refer to TS8 Assemblies. Implemented on serial numbers and above: TE242, PX072 and all TN. |
See Insert A on Drawing 10-4298AB. | |||||||||
| E115
(Apr 01) |
#11 (TS8) | Introduction of Universal Power Cord | N/A | For new installs only. See FCO E115. | See 16-4451 assembly drawing. | |||||||||
| E040
(Feb 01) |
N/A | Each service person will carry their own safety key and remove keys from installed machines. | Next visit | See FCO E040 for information. | ![]() |
|||||||||
| E010
(Jan 01) |
#10 (TS8) | Revised mechanical design of air jet plate to eliminate loctite. | On failure or debris removal upgrade. | See Trendsetter 800/400 Upgrade procedure, particulate ablative media. | See Air Jet Plate Assembly Drawing. | |||||||||
|
(Feb 01) |
N/A | Apply patent labels to all machines and heads. | Next visit | See Photos for label locations. | ||||||||||
| D955 | #8 | Autoloader V model and F model: revised carriage and drum motor plus power box changes | Next visit. | Applies to TE067, TE076, TE079 and TE089 | ![]() |
|||||||||
| D788
(Sep 00) |
#5 | Part # 18-3243, a rubber boot insulator, is a safety hazard and must be replaced with part # 18-3355. | ASAP | See FCO
D788 and the procedure
Order kit #05-0166.
|
![]() |
|||||||||
| D845
(Nov 00) |
#6 (TS8) | Debris removal for Trendsetter
3244+V to provide 1.3 min imaging time. Provides improved drum brake
system.
Spectrum requires a new rotary joint. |
As required | See
Trendsetter 800/400 Upgrade procedure, particulate ablative media.
Also see the following BOMs:
|
Debris removal cabinet present and functional. | |||||||||
| D874
(Oct 00) |
N/A | If the old reservoir system
springs a leak, replace using kit
#05-0183
.
For machines with new reservoir system, add strainer basket (#57-8167) |
Next Failure. To add strainer basket, Next Visit |
See
Water reservoir replacement procedure
.
Addition of strainer basket applies to all machines prior to TE0080 and Px0030. |
Check for strainer basket. ![]() |
|||||||||
| D547
(Jun 00) |
N/A | Version C of TEE board, 10-3627, has new pressure sensors. Service installations of version C board require firmware version 2.40. Version B boards can be used until stock runs out. | Next failure | See FCO D547 | Check board layout. See 10-3627C assembly drawing. | |||||||||
| D587
(May 00) |
#2 (TS8) | Low profile LEC (with lead-in
chamfer) to alleviate plate loading problems.
100-label number #2 on TS8 |
Next failure | Applies to SNs TE001 - TE035. Replace LECs only if adjustment of LECs does not fix plate load failures. Replace all six with part number 50-2114A (clamp body with dowels). | ![]() |
|||||||||
| D588
(May 00) |
#3 (TS8) | The engine manifold (50-1649A) uses a 4mm air jet line. The debris group will require a 6mm line. | FYI | Not backward compatible. Check manifold part number before ordering. | No visible change. Manifold part number is 50-1649B. | |||||||||
| D470 | #4 (TS8) | Revised reservoir and air ducting | As needed | See D874 for kit and instructions to upgrade. | ![]() |
|||||||||
| D210
(Oct 99) |
#26 | This ECO only applies to Kiel-built machines. | Spectrum only. | See instructions in FCO D210. | Not available. | |||||||||
| D023
(July 99) |
#24 | FCO C969 released a new engine and new load ramp configuration. To allow Kiel to use excess load ramp parts with the new engine, D023 releases a new engine and old load ramp configuration. | n/a | 100 label #24 or #23 indicate a machine with a new engine. For parts, refer to TS3/8 parts pages. | Check for factory installed 100 label number. | |||||||||
| C969
(June 99) |
#23 | Release of TS3/8 - with new engine. | n/a | For parts, refer to TS3/8 parts pages. | ![]() |
|||||||||
| C961
(July 99) |
#22 | Vacuum plugs on the drums cause
reflections.
Encoder is unreliable. |
Next visit | On next service visit, install
decals 74-3236A on all drums with vacuum seal discs behind the encoder
disc. See instuctions in FCO
C961
Replace encoder assemblies 32-3011B or 32-4047A with 32-4047B if encoder still failing after cleaning and aligning. |
||||||||||
| X1
(June 99) Note: The naming convention, X1, denotes that this is a swap of parts rather than a change to any part number. |
N/A | This FCO calls for the replacement of the — TEC backbone, 50-1088A — on 81 output devices including Platesetters, Trendsetter, and Proofsetters. The TEC backbones on these output devices are all from the same batch lot assembled with the wrong type of Loctite that will eventually cause them to loosen and fail over time. | Next visit | Treat this FCO as a recall: schedule a visit, replace the assembly, and return the old assembly to Creo Annacis for refurbishing. | N/A | |||||||||
| C953
(June 99) |
#19 | The existing TS3 machine with a
1.7 head does not satisfy European emission standards. This FCO releases a
kit to upgrade a machine to compliance.
|
Next visit | Applies to all TS3244 machines with 1.7 heads. See EMI Upgrade Procedure. Implemented on production machines ~S313. | Photo | |||||||||
| C942
(June 99) |
N/A | Release of Encoder Cleaning Kits:
• Encoder/lens cleaning kit (04-0012B) • Encoder cleaning kit (04-0014A) (includes 04-0012B) |
n/a | See Optical encoder cleaning procedure | Not available | |||||||||
| C933
(July 99) |
N/A | Upgrade from TS3244_ or TS3244F to TS3244V | n/a | n/a | Not available | |||||||||
| C904
(June 99) Kit 05-0105 |
N/A | Customers can't always find the machine serial number when placing a call to the response center. | Next visit | Attach a label with a Service Reference Number to each machine in the field. See instructions in FCO C904. | Not available | |||||||||
| C890
(June 99) |
N/A | New part number for servoamp: 15-3330A replaces 15-3114A. Identified with blue dot. | On failure | Replace only if a problem arises
or you cannot calibrate the servo amp using the "drum cal"
command.
Note: Firmware that supports "drum cal" (drum module 1.11 or higher) is a pre-requisite for implementing this FCO. |
Servoamp 15-3330A. Identified with blue dot. | |||||||||
| C853
(May 99) Kit 05-0108 |
#20 | All shipped TS3-based units that have the 1.7 water-cooled head option have a 2" air cooling hole. This hole is a potential laser safety problem and must be fitted with a blocking plate. | Next visit | Install blocking plate. See the Water Cooling Kit Laser Blocking Plate Install Assembly Drawing . | ||||||||||
| C716
(Feb 99) |
N/A | Wave washer between the TEC cylinder and slider bracket may break. Solution: remove wave washer. | TBD | Field upgrade. See procedure in C716 | ||||||||||
| C694
(Mar 99) |
N/A | Adds SPI filters to the Trendsetter Interface
board 10-1419C.
The SPI filter daughter boards (10-3647A and 10-3669A) reduce the effect of high frequency noise. |
Next Call | Required on S65 and earlier for CE compliance
to ESD noise. Replaces FCO B747 |
Trendsetter Interface board 10-1419C | |||||||||
| C674 | #17 | New drum roller (57-2209D) with a smaller diameter on the ends. | Next failure | Replace drum roller. | Drum roller part number 57-2209C or higher | |||||||||
| C624
(Dec 98)
|
N/A | For certain trendsetter sites running film, the system blower is causing the film to buckle during loading. The temporary solution of disconnecting the fan is not desirable. FCO C624 adds a fan baffle to the system blower so flow is directed away from the edge of the drum and the film. | Next visit at customer sites running film. | Any Trendsetter running film with a squirrel cage fan and no TEE board requires this upgrade. The squirrel cage fan can be identified by the square cutout in the back of the fanbox. The affected machines are S94-S161. | Check serial numbers S94-S161 for fan baffle on the system blower | |||||||||
| C572
(May 99) Field Upgrade Kit: 05-0067 (JV-Grey), 05-0068 (Creo-Grey) |
#15 | Install Spectrum Machine Back Panel | Next visit | Trendsetters in the field without the panel (mostly Spectrums) should have this panel added at the next call. | ||||||||||
| C371
(July 98) |
#10 | The current hotlink cable (16-3532) is replaced with a stranded core coax cable (16-3532A-A) to improve reliability. | Medium | Replace as required on S207 and lower | ||||||||||
| C341
(June 98) |
N/A | In order to support the higher drum speeds required by the 3.0 minute thermal head, early Trendsetters must be retrofitted with stiffer engine mounts. | Implemented on SP1 and S150. | |||||||||||
| C281
(April 98) |
N/A | Use of desiccant box on the head to remove moisture and reduce condensation. | ||||||||||||
| C232 | #8 | EMI modifications | Production only. | ![]() |
||||||||||
| C191
(March 98) |
N/A | Optional external alarm kit | ||||||||||||
| C144
(Feb. 98) |
N/A | The thermal DPE board and the PHI board are being replaced by the new FDPE (Fast Data Path Electronics) board. | On failure | To replace the DPE board:
|
||||||||||
| C087 | Feb. 98 | Autoloader field install kit | ||||||||||||
| C051 | #3 Jan 98 | New pushbutton on the Trendsetter
3244
OIF board(10-1420B) and cable(10-3187) |
info only | Brown wire connects to button LED
pin X1
Red wire connects to button LED pin X2 Black wire connects to contact pin 13 White wire connects to contact pin 14 |
||||||||||
| C041 | Jan. 98 | Implement metric tube sizing on the Trendsetter 3244 | ||||||||||||
| C039
(Dec. 97) |
#3 | Release of the new 10-3627A TEE board | ![]() |
|||||||||||
| B991 revised
(May 98) |
#1 | Implement a Service Interlock Override (SIO)
keyswitch assembly for the Trendsetter power box, to meet the following
requirements:
|
This revision to FCO # B991 must be implemented
for all Trendsetters in the field. Refer to the Mainframe-Electronics Schematic
and the Powerbox Schematic
during the procedure.
To ease in any future upgrade to the Spectrum or Autoloader options, the SIO installation procedure requires routing two additional cable assemblies via the power box flex track. |
![]() |
||||||||||
| B931
(Oct. 97) |
N/A | See CA01804 | ||||||||||||
| B856
(Sep. 97) |
N/A | Introduction of Uptime Spares kit (02-4258A) for customers who want to keep their own spares. It is expected that the kit will cover 80% level of service. | None | |||||||||||
| B838
(Sep. 97) |
N/A | New front panel used with the proofer option. Will be implemented on S109 and Kiel machine SK001. | None | |||||||||||
| B830
(Aug. 97) |
N/A | New part numbers for the MPE and ALE boards | On failure. You can replace an old
board with a new one as long as the firmware version is 2.07 a/b or
higher.
|
|||||||||||
| B820
(Sep. 97) |
N/A | Design change on shutter (plate exit door). Not backward compatible. | None | |||||||||||
| B812
(July 97) |
N/A | Major changes to the power box and mainframe so that the base Trendsetter 3244 can be upgraded with the Proofer or Autoloader option. | Instructions to upgrade fan cooling system in the field
Field upgrades required for these 6 units even if they are not to be converted to Trendsetter Spectrum:
|
|||||||||||
| B768
(June 97) |
N/A | Upgrade of the the PS1 power supply (10-3213) in Trendsetter 3244/3230, Autoloader and Spectrum machines from a Vicor FlatPac style design to a Power One open frame type. See upgrade procedure. | Next visit | This upgrade is not mandatory for all Trendsetters and should only be carried out if a replacement Vicor FlatPac is not available for exchange. | ||||||||||
| B747
(Sept 97) |
N/A | See C694 | ||||||||||||
| B713
(July 97) |
N/A | New version of reed switch tester (10-3622B). New tester has a longer cable and includes a hall effect tester. | ||||||||||||
| B626
(Jun 97) |
N/A | Power cord changed from 16-3785(15A) to 16-3772(20A) | Applies to TS6 and higher | |||||||||||
| B624
(July 97) |
N/A | Removal of the thermal blower mesh to prevent restricted airflow through head. | Applies to Trendsetter 3244 serial numbers S1 to S65. Trendsetter 3244 fanbox upgrade | |||||||||||
| B555
(May 97) |
N/A | Changes to power box to provide hooks for the autoloader and proofer options. | Applies to S66 and higher. | |||||||||||
| B296
(Jan. 97) |
N/A | Updates to power box (11-0442B). | ||||||||||||
| B104
Nov. 96 |
N/A | Latch upgrade | Yes | |||||||||||
| A829
(Aug. 96) |
N/A | Plate alignment sticker placement | Yes | |||||||||||
| A738
(July 96) |
N/A | Replace incorrect voltage label in fan box | Yes |