Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
07 Dec 2006: Wrist cylinder upgrade procedure for FCO CA00567 revised More...
The Wrist Cylinder Upgrade for FCO CA00567 has been revised to correct an error. Previously, the procedure instructed service engineers to thread the clevis onto the cylinder shaft, leaving three threads visible after it was locked down by the jam nut. However, three threads is not a sufficiently consistent measure, and could result in retracted wrist cylinders being different in length, causing skew in plate loading. The corrected procedure instructs service engineers to thread the clevis onto the cylinder shaft so that the end of the shaft is flush with the open end of the clevis.
12 Dec 2006: GMCE Controlled Release 2.1 More...
Trendsetter 400/800/NEWS - GMCE Controlled Release 2.1 for GMCE Trendsetter 400/800 III base, Autoloader, ContinuousLoad, and NEWS is posted on the Control/Settings page. GMCE CR 2.1 includes an update for the DCAPI server. This CR can only be installed on GMCE devices.
28 Nov 2006: Translated safety guide and visual reference guide posted More...
Translations of the Trendsetter Autoloader Visual Reference Guide and Safety Guide for customers are available on the Reference page.
14 Nov 2006: GMCE Trendsetter production starting 15 Nov 2006 More...
Trendsetter 400/800 III with serial numbers starting with TG are in production effective 15 Nov 2006. GMCE information has been added throughout the site including:
Additional updated information and translations will be posted to the site as they are available.
TechPlanet DVD Version 5 N.301 Nov 2006
06 Oct 2006: FCO CA10840: New picker up down sensor kit More...
A new picker up down sensor kit (part number 518-01911A) for MCE devices has been created due to reliability problems with picker sensor 10-3676A. See FCO CA10840 on the FCOs page for the kit number and procedure. This is a next failure FCO.
21 Jun 2006: Controlled Release 5.3 More...
Trendsetter 400/800 Controlled Release MCE 5.3 for MCE Trendsetter 400/800 base, Autoloader, ContinuousLoad, Spectrum, and Auctus is posted on the Control/Settings page. MCE CR5.3 includes service dongle control of Service Shell and supports a minimum mainscan size of 270 mm on manual devices. See the Trendsetter MCE Controlled Release 5.3 Readme/Release Notes for more information.
07 Jun 2006: Site preparation guides More...
The English versions of the Trendsetter Autoloader Site Preparation Guide and Trendsetter Autoloader Spectrum Site Preparation Guide have been updated and posted on the Installation page. The revisions include improved footprint and work area diagrams, and corrections to electrical connector information for Europe and United Kingdom.
02 Jun 2006: Trendsetter Autoloader specifications updated More...
The Trendsetter Autoloader and KRS specifications have been revised to include X-speed and updated performance information. See the Overview page.
TechPlanet DVD Version 5 N.201 Jun 2006
26 May 2006: Processor interface guide More...
The new Trendsetter AL, CL, and NEWS Processor Interface Guide has been posted on the Installation page. This document describes the electrical connections, firmware requirements, installation procedure, and operation of the processor interface between a Trendsetter NEWS, AL, or CL output device and a Glunz & Jensen or Agfa Lithostar processor.
11 May 2006: New MCE geometric correction parameters document More...
A new document describing the MCE firmware parameters used to adjust geometric correction on Trendsetter 400/800 II, Autoloader, ContinuousLoad, Spectrum, and NEWS output devices has been added to the Base Trendsetter Procedures page.
10 May 2006: Static balancing of the drum in the field More...
A procedure for static balancing of the drum in the field has been added to the Base Trendsetter Procedures page. This procedure may be required in situations where there is excessive device vibration. Kit number 518-01763A is required to complete this procedure.
21 Mar 2006: Trendsetter MCE Controlled Release 5.2 and Trendsetter AL MPE Controlled Release 2.3 More...
Trendsetter MCE Controlled Release 5.2 and Trendsetter AL MPE Controlled Release 2.3 are posted on the Control/settings page. Information on major features and fixes is included in the MCE Trendsetter 4/8 Controlled Release 5.2 Readme/Release notes and MPE TRENDSETTER 4/8 AL CONTROLLED RELEASE 2.3 Readme/Release Notes.
13 Mar 2006: Japanese translation of the Trendsetter Autoloader Site Preparation Guide More...
See the Installation page for the Japanese translation of the Trendsetter Autoloader Site Preparation Guide.
09 Mar 2006: FCO CA09416: Repair kit for broken unload table outrigger bracket More...
See FCO CA09416 on the FCOs page for the kit number and procedure.
07 Mar 2006: Operator and visual quick reference guides available in simplified Chinese More...
See the Reference page for the simplified Chinese translation of the Trendsetter AL operator and visual quick reference guides.
20 Feb 2006: Controlled Release 5.0 and 5.1 field upgrades More...
Before doing a field upgrade to CR 5.0 or 5.1, you must be familiar with the requirements and processes for installing Creo Feature Licensing. See Trendsetter 400/800 Controlled Release MCE 5.0 and Trendsetter 400/800 Controlled Release MCE 5.1 on the Control/Settings page.
16 Feb 2006: Creo Feature Licensing (CFL) information More...
A site about Creo Feature Licensing (CFL) replaces the Creo Feature Licensing page. Click Feature Licensing under Related sites in the side menu to access the CFL site.
TechPlanet DVD Version 5 N.1 and Mature Products 200631 Jan 2006
30 Jan 2006: Translations of the Trendsetter Autoloader Site Preparation Guide More...
See the Installation page for Dutch, French, German, Spanish, Italian, and Chinese versions of the Trendsetter Autoloader Site Preparation Guide.
20 Jan 2006: Delicate Media Upgrade for MCE Trendsetter AL More...
The delicate media upgrade has been designed to reduce possible scratches caused by certain plate types rubbing against each other during the picking/loading sequence on MCE Trendsetter Autoloader devices. For more information, see Upgrades on the Procedures page.
20 Dec 2005: Update 1 for Trendsetter 400/800 base, AL, CL, and Spectrum Controlled Release MCE 4.1 More...
This update fixes a flyoff problem for Spectrum devices and reduces the hold current of the unload table traveller motor to prevent the motor from overheating on Autoloader and ContinuousLoad devices. See Trendsetter 400/800 Controlled Release MCE 4.1, Update 1 on the Control/Settings page.
14 Dec 2005: Trendsetter MCE Controlled Release 5.1 More...
CR 5.1 is a factory-installed controlled release for MCE Trendsetter 400/800 base, Autoloader, ContinuousLoad, Spectrum, and Auctus. Do not upgrade to this release in the field unless 5.0 is installed or it is an X-speed upgrade. Information on major features and fixes is included in the MCE TRENDSETTER 4/8 CONTROLLED RELEASE 5.1 Release Notes.
25 Nov 2005: Trendsetter Autoloader and Trendsetter Autoloader Spectrum site preparation guides updated More...
The Trendsetter Autoloader Site Preparation Guide and Trendsetter Autoloader Spectrum Site Preparation Guide, posted on the Installation page, have been updated with Kodak branding, more accurate dimensions and weights for output device and shipping crates, and information about the compact shipping option.
TechPlanet DVD Version 4 N.330 Sep 2005
03 Oct 2005: Trendsetter MCE Controlled Release 5.0 More...
CR 5.0 is a factory-installed controlled release for MCE Trendsetter 400/800 base, Autoloader, ContinuousLoad, Spectrum, and Auctus.
CR 5.0 factory installation started at serial number TM894. CR 5.0 was also installed during the beta and prerelease stages on TM741, TM744, TM749, TM753, TM764, TM869, TM870, TM871, TM872, TM873, TM876, TM877, TM879, TM880, and TM883. Information on major features and fixes is included in the MCE TRENDSETTER 4/8 CONTROLLED RELEASE 5.0 Readme/Release Notes.
20 Sep 2005: FCO CA08150: Picker wrist stopper upgrade More...
FCO CA08150 releases an upgrade to fix the following problem.
If a Trendsetter AL has picking problems due to movement of the the picker wrist stoppers over time, add a new, reinforced bracket to the picker wrist assembly to hold the stoppers in place more securely. See procedure . FCO CA08150 is a Next Failure FCO.
16 Aug 2005: New Mylar strip for Picker 3 to reduce suction cup marks on Fuji LH-PI plates More...
Part number 252-08408A is a Teflonฎ-coated, Mylarฎ strip for Picker 3 that reduces suction cup marks on Fujiฎ LH-PI plates and other positive plates with a very delicate emulsion. FCO CA07801 is a next failure FCO.
15 Aug 2005: Trendsetter MCE Controlled Release 4.1 More...
This controlled release is for MCE Trendsetter 400/800 base, Autoloader, ContinuousLoad, and Spectrum. MCE Trendsetter 400/800 base, AL, CL, and Spectrum is posted on the Control/settings page. Information on major features and fixes is included in the MCE TRENDSETTER 4/8 CONTROLLED RELEASE 4.1 Readme/Release Notes.
07 Jul 2005: Escalation contact information for CAP updated More...
The CSC-PSS contact information for CAP has been updated on the Escalation page. The e-mail address has changed and separate phone numbers for Australia and Shanghai are now available.
17 Jun 2005: Troubleshooting: MCE error 40016: SMC: Motor unexpectedly hit the away sensor More...
If firmware error 40016 occurs on an MCE Trendsetter 400/800 II AL device that has just had a new controlled release installed, it is likely that the device is still using the old 24-tooth unload table stepper motor pulley, which is not compatible with the latest default NVS parameters. The solution is to temporarily modify the mhauto UnloaderMSR and mhauto UnloaderSPM parameters to match the old defaults and replace the 24-tooth pulley with the new 16-tooth pulley as soon as possible ( FCO CA02183 ).
If error 40016 occurs and the device has not just had a new controlled release installed, the problem could be with the home-side unload table table motor sensor or cable.
See the troubleshooting item, posted on the Troubleshooting page, for more information.
13 Jun 2005: FCO CA07202: Bracket to improve position of picker down sensor for better reliability More...
The foam tape used to block the picker down sensor signal can cause intermittent sensing problems. Order kit number 512-00288A with a bracket that moves the sensor to a better location. See FCO CA07202 on the FCOs page.
TechPlanet DVD Version 4 N.231 May 2005
25 May 2005: Trendsetter 400/800 AL Visual Quick Reference guide for TS8 MPE devices More...
See Trendsetter 400/800 AL Visual Quick Reference guide for TS8 MPE devices (part number 653-00954A-EN-A) on the Reference page.
03 May 2005: Troubleshooting: Plates moved on unload table before rotation complete More...
See the troubleshooting item on the Troubleshooting page.
27 Apr 2005: Installation test checklist for customers and revised installation test procedure posted More...
Service engineers should fill out the new customer installation test checklist (ITC) during the installation test procedure (ITP), have customers sign the checklist, and leave a copy of the checklist on-site. The ITC and revised ITP for Creo service are posted on the Installation page. Translations of the checklists will be posted when they are available.
26 Apr 2005: FCO CA06235 revised: picker head cylinder replacement kits removed More...
Order kit number 518-01238A to replace picker head in/out cylinders. Order field service kit (number 512-00263A) to replace the upper load ramp cylinders. See FCO CA06235 for details.
07 Apr 2005: Trendsetter MCE Controlled Release 4.0 More...
This controlled release is for MCE Trendsetter 400/800 base, Autoloader, ContinuousLoad, and Spectrum. Trendsetter 400/800 MCE Controlled Release 4.0 is posted on the Control/settings page. Information on major features and fixes is included in the MCE TRENDSETTER 4/8 CONTROLLED RELEASE 4.0 ReadMe/Release Notes.
Note that a service dongle is required for some components in CR4.0. Service dongles will be required for future CRs so you should order one soon. See Creo Feature Licensing for ordering information.
31 Mar 2005: Trendsetter AL MPE Controlled Release 2.2 available More...
Trendsetter AL MPE Controlled Release 2.2 is posted on the Control/settings page. Information on major features and fixes is included in the Readme/release notes for Trendsetter AL Controlled Release 2.2. Note that CR 2.0 and CR 2.1 have been withdrawn.
23 Mar 2005: FCO CA06235: Load ramp and picker head cylinder replacement kits for better reliability More...
FCO CA06235 releases field service kits for replacing the upper load ramp cylinders (part number 512-00263A) and picker head in/out cylinders (part number 512-00264A). The priority of this FCO is Next Failure.
28 Feb 2005: FCO CA06533: Field service kit for replacing the unload table traveler motor on MCE devices More...
FCO CA06533 releases a field service kit (part number 512-00256A) for replacing the unload table traveler motor on MCE devices (serial numbers begin with TM). The priority of this FCO is Next Failure.
25 Feb 2005: Revised specifications and site preparation guide More...
The Trendsetter II Autoloader Specifications and Site Preparation Guide have been revised. Find the Specifications document on the Overview page and the Site Preparation Guide on the Installation page.
03 Feb 2005: Trendsetter MCE Controlled Release 3.4 More...
This controlled release is for MCE Trendsetter 400/800 base, Autoloader, and Spectrum. CR3.4 includes Thermal Head v1.97 firmware, and Xilinx 2.23. TH 1.x 1.95 firmware had an issue where if the device used multiple media (either plating or proofing), the stroke tables were corrupted. This corruption could result in banding on plate or proof and could be easily misdiagnosed. This is corrected in 1.97. For details, see Trendsetter MCE Controlled Release version 3.4 posted on the Control-Settings page.
TechPlanet DVD Version 4 N.1 and Mature Products 200531 Jan 2005
20 Dec 2004: Trendsetter MPE Controlled Release 2.1 More...
This controlled release is for MPE Trendsetter Autoloader. CR2.1 includes MPE v1.56 firmware, Thermal Head v1.95 firmware, Print Console v2.4, and Service Shell v2.5 SP2. For details, see Trendsetter MPE Controlled Release version 2.1 on the Control-Settings page.
17 Dec 2004: Using the scan <I/O> command to diagnose MCE sensor states More...
A new procedure, Interpreting MCE Sensor I/O Bit States , has been posted on the Procedures page. This document describes how to use the scan <I/O> command to display sensor input bit names and interpret the results.
09 Dec 2004: Replacing the picker guide cables More...
A new procedure, Replacing the Picker 3 guide cables , has been posted on the Procedures page.
08 Dec 2004: FCO CA06076: Replace MCE device unload table stepper motor cable More...
FCO CA06076 replaces the MCE device unload stepper motor cable (10-4855A-A) with a new cable (10-4855B-A). The new cable has better contacts in the motor-side IDC connector, which prevents the cable from heating up, melting, and possibly damaging the stepper motor. This FCO has a priority of Next Visit.
Note: This FCO supersedes FCO CA04962.
08 Dec 2004: Troubleshooting: MCE Error #43308: CRG: Carriage travel limit (<xxx>) unexpectedly hit More...
This troubleshooting item describes the actions to perform for service engineers, the Response Center, and shared maintenance customers (where applicable) when this error occurs.
Find a link to this document on the Base Trendsetter Troubleshooting page.
02 Dec 2004: Warning: TH1.x Head Firmware Stroke table corruption occurs when switching media, causing image artifacts or banding More...
This affects Thermal 1.x heads with head firmware version 1.93, 1.95, or 1.96 and LVD hardware version 4 or later
If all of the above conditions apply, and the device has more than one media setup, when you switch media the stroke tables may become corrupted and display all 33s. This can cause image artifacts or banding.
If the device you are working on meets all the conditions above and has more than one media setup, even if you are not experiencing image artifacts or banding, complete the following workaround:
Workaround
stroke.head version. You're looking for a Thermal 1.x head with:
set head r6 0.r6 does not exist: Type set head lvreverse 0.nvs save head.The 33s in the stroke tables are active and have not been saved, so resetting the device will clear them. After resetting the device the head will perform a stroke cal automatically on the first plot as each media is selected.
A permanent solution will be rolled out in the next two weeks.
02 Dec 2004: Revised site preparation guides posted More...
The Site Inspection Checklist section of the Site Preparation PDF now contains text fields and check boxes that you can fill in online. See the installation page for details.
26 Nov 2004: FCO CA04962: Replace unload table stepper motor cable on TSM devices More...
FCO CA04962 replaces the unload stepper motor cable (10-4855A-A or A-B) with a new cable (10-4855A-C). The new cable has better contacts in the motor-side IDC connector, which prevents the cable from heating up, melting, and possibly damaging the stepper motor. This FCO has a priority of Next Visit.
Note: This change is not being tracked via the ECO 100 Label.
08 Oct 2004: New troubleshooting item: Carriage driver board 503C01525B power supply feeds noise into MCE board More...
A new troubleshooting item has been posted on the Base Trendsetter Troubleshooting page, describing the procedure to perform when one or more of the following symptoms occur:
04 Oct 2004: FCO CA05160 released: carriage driver board cable replacement More...
FCO CA00752 introduced a new carriage driver board (503C01525B), which has a switching power supply that generates a high level of electrical noise. This noise is fed into the MCE board via carriage driver board power cable 220-00061A, which can cause SCSI CRC check errors, digital I/O errors, and low-level firmware errors.
FCO CA05160 corrects this problem by replacing the carriage driver boards power cable with one that connects directly to the power supply instead of a point on the MCE board.
Note: The procedure for FCO CA00752 has also been updated with information about the new cable and how to connect it.
TechPlanet CD Version 3 N.330 Sep 2004
20 Sep 2004: New procedure for status lights feature upgrade posted More...
The Status Lights Upgrade Procedure for Trendsetter Autoloader and NEWS Devices has been posted on the Procedures page. This is a feature upgrade that customers may purchase in order to upgrade their NEWS or Autoloader devices to use the new, multicolored status lights.
20 Sep 2004: Trendsetter MCE Controlled Release 3.3 More...
This controlled release is for MCE Trendsetter 400/800 base, Autoloader, and Spectrum. CR3.3 includes MCE v1.18.15 firmware, Thermal Head v1.95 firmware, Xilinx 1.4, and Service Shell v2.5 SP1. For details, see Trendsetter MCE Controlled Release version 3.3 posted on the Control-Settings page.
20 Sep 2004: Trendsetter AL MPE Controlled Release 2.0 More...
This controlled release is for MPE Trendsetter Autoloaders and includes MPE v1.54 firmware, Thermal Head v1.95 firmware, Brisque Agent v1.0, and Service Shell v2.5 SP1. For details, see Trendsetter AL MPE Controlled release version 2.0 posted on the Control-Settings page.
30 Aug 2004: Safety Procedures for Service Engineers More...
You must follow Safety Policies for Service Engineers posted on the Safety page to protect yourself, your co-workers and customers.
18 Aug 2004: Checking GENINE board installation More...
When installing the GENINE board, the plastic film MUST be removed from the heat sinking compound on the back of the board. Failure to remove this film can lead to unexpected resets or premature failure of this board. For devices built between 1 April 2004 and 20 July 2004, please verify that the GENINE board has been installed correctly. See Checking GENINE board installation on the base Trendsetter Procedures page
17 Aug 2004: New procedure: Replacing/repositioning plate ledge teeth More...
A new procedure for replacing or repositioning the load table's plate ledge teeth has been added to the Procedures page.
12 Aug 2004: New troubleshooting items More...
The following troubleshooting items have been added to the Troubleshooting page:
06 Aug 2004: New procedures posted More...
The following new procedures have been posted on the Procedures page:
Measuring engine, picker, and table actuator times and adjusting actuators
Related procedures:
Adjusting the load ramp in/out actuator regulators
Adjusting the Picker 3 Up/Down Actuator Regulators
Adjusting the Picker 3 In/Out Actuator Regulators
Adjusting the separator in/out actuator regulators
Adjusting the table rotate on/off actuator regulators
28 Jul 2004: Trendsetter AL Visual Quick Reference posted More...
See the Reference page.
09 Jul 2004: Trendsetter AL/NEWS PM Procedure updated More...
The Picker 3 section of the PM procedure has been revised to add a step for checking and adjusting the distance between the picker head and the load table after a picker in command. If this distance is less than 25-30 mm, plate double-picking may occur.
Posted on the Maintenance page.
05 Jul 2004: Trendsetter MCE Controlled Release 3.2 Update 1 More...
This update should only be installed to fix specific UDRC problems with Controlled Release 3.2. For details, see the Control-Settings page.
05 Jul 2004: FCO CA04191: Plate bay door hinge and gas strut upgrade More...
FCO CA04191 releases a kit for upgrading the hinges and gas struts on the plate bay door. This upgrade addresses the issues described in the Product Safety Alert posted on 18 Mar 2004.
The priority of this FCO is ASAP.
TechPlanet CD Version 3 N.214 Jun 2004
10 Jun 2004: New procedures posted More...
The following new procedures have been posted on the Procedures page:
Replacing vacuum cups on Picker 3
Measuring the picker vacuum level and setting the vacuum level threshold
Replacing the autoloader unload table vacuum cups
Measuring the unload table vacuum level and setting the vacuum threshold
10 Jun 2004: New/updated troubleshooting procedures for plate double-picking posted More...
The following new troubleshooting procedures for plate double-picking have been posted on the Troubleshooting page:
Eliminating external (to the output device) causes of plate double-picking
Plate double-picking on Picker 3 due to improperly adjusted picker head travel distance
Also, the following troubleshooting item has been updated to include the latest FCO (CA00567, wrist cylinder upgrade) for solving picker 3 double picking and picker vacuum timeout errors:
Picker 3: Wrist or picker head in/out cylinders leaking
20 May 2004: Problem with CR 3.2automatic load calibrate does not work More...
The release notes for the MCE firmware included in Controlled Release 3.2 instruct you to enter command load cal to have the device set the mh DistSensorToLEC parameter during an automatic load. However, there are two problems with this command. First, it should be load calibrate (assuming the previous load was an automatic load), and second, this command does not work in this firmware release. The plate is picked, but the picker never goes down and the device hangs. Thus, it is necessary to do a manual load calibrate to set the mh DistSensorToLEC parameter.
See the Known problems section of CR 3.2 for more information.
19 Apr 2004: Revised and New Specifications More...
The Trendsetter II Autoloader Specifications have been revised and Creo Remanufactured Solutions (CRS) Specifications have been added to the Overview page:
18 Mar 2004: Safety Alert for customers regarding plate bay hinges More...
This problem was corrected with FCO CA04191 (July, 2004)
A Product Safety Alert to notify customers of a potential safety hazard on Trendsetter Autoloader and NEWS devices was sent to customers on 17 Mar 2004. Safety Alert From Creo: Trendsetter Autoloader and Trendsetter NEWS plate bay hinges went to all Trendsetter customers on the eCentral mailing lists and has also been posted on the Safety and Reference pages. Please encourage your customers to sign up for eCentral so that they can receive any future Alerts. Use Plate bay hinge inspection and replacement to inspect all of your TS AL sites.
15 Mar 2004: Plate bay hinge inspection and replacement More...
This problem was corrected with FCO CA04191 (July, 2004)
The hinge that supports the plate bay door is subjected to heavy loads that can lead to excessive wear on the hinge pin causing premature failure. This should be inspected on all TS AL devices.
See Plate bay hinge inspection and replacement. This document is posted on both the Maintenance and Procedures pages. The PM procedure has been revised to add more information on this inspection.
15 Mar 2004: Revised PM and Uptime/Spares information More...
Updated Planned Maintenance kits and PM procedure are posted on the Maintenance page and Uptime/Spares kits are on the Parts page. See Trendsetter 400/800 PM kits - Excel spreadsheet, Trendsetter Autoloader/NEWS Planned Maintenance Procedure and Trendsetter Uptime/Spares Kits - Excel spreadsheet.
08 Mar 2004: Revised Specifications More...
Specifications have been updated. See the Overview page.
08 Mar 2004: Lastra LT-2/KPG LT-3 no longer qualified on Trendsetter Autoloaders with P3 pickers More...
Lastra LT-2/KPG LT-3 is no longer qualified on Trendsetter Autoloaders with P3 pickers. See the latest tech note: Invalid Key
TechPlanet CD Version 3 N.129 Feb 2004
04 Feb 2004: Trendsetter MCE Controlled Release 3.2 More...
This controlled release is for MCE Trendsetter 400/800 base, Autoloader, and Spectrum. CR3.2 includes MCE v1.18.10 firmware, Thermal Head v1.93 firmware, and Service Shell v2.5. For details, see the Control-Settings page. This is a next visit FCO.
19 Nov 2003: Trendsetter MCE Controlled Release 3.0 More...
This controlled release is for MCE Trendsetter 400/800 base, Autoloader, and Spectrum. CR3.0 includes MCE 1.18 firmware, and Service Shell 2.5. For details, see the Control-Settings page. This is a next visit FCO.
18 Nov 2003: Upgrade unload table pulley and belt guide More...
On MCE devices, the 16-tooth unload table pulley can prevent stalling and the belt guide for non-rotator Autoloaders can reduce belt wear. See FCO CA02183 for details.
25 Sep 2003: MOVs and spark gaps are being removed from devices (ECO CA01804) More...
Creo MPE devices are no longer being shipped with metal oxide varistors (MOVs) and spark gaps between line and ground. The MOV assemblies should be removed from units in the field (serial numbers TE 799 and earlier) at the next PM visit. See FCO CA01804 for details.
TechPlanet CD Version 2 N.3/415 Sep 2003
15 Sep 2003: Problem With Backing Up NVS Parameters When Using Service Shell v2.4 SP1 More...
The installer file for Service Shell v2.4 SP1 is generating an error message when NVS parameters are backed up. The message will read:
29 Aug 2003: Trendsetter MCE Controlled Release 2.0 More...
CDs are now available for Controlled Release MCE 2.0 for the Trendsetter 400/800, Trendsetter AL and Trendsetter Spectrum. This controlled release is the early production release for MCE Spectrum and includes MCE 1.14 firmware and Media Console version 1.2. For details, see the Control-Settings page. This is a next visit FCO.
11 Aug 2003: Dutch Translation of Trendsetter AL (TSM version) Operator Manual posted More...
See the Reference page for Dutch version of the Trendsetter AL (TSM version) Operator Manual.
25 Jul 2003: Trendsetter MCE Controlled Release 1.2 More...
CDs are now available for Controlled Release MCE 1.2 for the Trendsetter 400/800 and Trendsetter AL. The MCE 1.2 controlled release includes Print Console 3.4 and MCE firmware required for Brisque 4.1. For details, see the Control-Settings page. This is a next visit FCO.
11 Jul 2003: Translations of Trendsetter AL PM Checklist for Customers More...
See the Maintenance page for French, German, Spanish, Italian, and Japanese versions of the Trendsetter AL Planned Maintenance Checklist for Customers.
03 Jul 2003: Translations of Trendsetter AL (TSM version) Operator Manual posted More...
See the Reference page for French, German, Spanish, Italian, and Japanese versions of the Trendsetter AL (TSM version) Operator Manual.
24 Jun 2003: Trendsetter MCE Controlled Release 1.2 not available at this time
29 May 2003: Trendsetter MCE Controlled Release 1.2 More...
CDs are now available for Controlled Release MCE 1.2 for the Trendsetter 400/800 and Trendsetter AL. The MCE 1.2 controlled release includes Print Console 3.4 and MCE firmware required for Brisque 4.1. For details, see the Control-Settings page. This is a next visit FCO.
07 May 2003: Trendsetter 400/800 MCE Controlled Release 1.1 More...
CDs are now available for Controlled Release MCE 1.1 for the Trendsetter 400/800 and Trendsetter AL. The MCE 1.1 controlled release includes updated Xilinx firmware code (1.65) and Service Shell 2.4 Service Pack 1. For details, see the Control-Settings page. This is a next visit FCO.
01 May 2003: Planned Maintenance Checklist for Customers More...
In response to customer requests, an initiative is underway to improve how scheduled maintenance is documented and tracked. One part of the initiative is to ensure that every device is checked for safety and overall operation first, before each assembly is assessed and cleaned/fixed. Once the PM work is finished, the customer is given a list of what has been done and asked to sign off on it. The advantage to Creo is that once the signed PM documents are filed centrally, we have a complete maintenance history for each machine.
The new customer checklist is to be filled out by the service engineer during a PM visit, signed by the customer, and a copy left on site. The customer PM checklist and procedures for Creo service are on the Maintenance page.
TechPlanet CD Version 2 N.228 Apr 2003
14 Apr 2003: Communication or air flow problems with the UDRC-LC (chemistry-free option) More...
If the Trendsetter 400/800, Trendsetter AL, or Trendsetter Spectrum device is unable to communicate with the UDRC-LC (chemistry-free option), or an error of a possible leak or blockage in air flow is reported, the Lionel board should be hard reset. For details, see UDRC-LC on the Debris Removal Troubleshooting page.
08 Apr 2003: Trendsetter II Autoloader specifications More...
Trendsetter II Autoloader specifications are available on the Overview page.
03 Apr 2003: Type II performance improvements More...
Information regarding sales and marketing, order management and customer support, as well as an FAQ regarding the new performance has been compiled at Performance improvements with 8 page CTP
28 Mar 2003: Trendsetter MCE Information Page More...
This page contains information that is specific to Trendsetter MCE devices. Note that the terms Type II, TSM, and MCE are all used to refer to Trendsetter MCE in Trendsetter documentation.
All of the information listed on Trendsetter MCE Info is also available on the relevant pages within the Trendsetter 400/800, Trendsetter AL and Trendsetter NEWS sites.
19 Mar 2003: Autoloader wrist cylinder upgrade and vacuum generator kit. More...
A wrist cylinder upgrade kit for improved reliability and a kit for replacing the discontinued vacuum generator have been released. See FCO CA00567 for kit numbers and procedure.
25 Feb 2003: Recommended carriage settings for MCE devices More...
Please ensure that all Trendsetter MCE devices have the carriage parameters set according to the carriage settings table on the Control/Settings page.
24 Feb 2003: New carriage motor for MCE Trendsetter NEWS and Autoloaders. More...
Kit 512-00031 includes stepper motor and pulley assembly and cable adapter. See FC0 CA00482 on the FCOs page.
11 Feb 2003: Trendsetter AL MPE Controlled Release 1.1 More...
The second MPE Controlled Release CD is now available for the Trendsetter AL. This Controlled Release includes version 1.83 firmware for Thermal Head 1.7 and Service Shell 2.4. For details, click on MPE Controlled Release version 1.1 on the Control-Settings page.
TechPlanet CD Version 2 N.125 Jan 2003
24 Jan 2003: TSM (MCE) Specifications, Operator Manual and Site Prep posted More...
Specifications, Operator Manual and Site Prep documents for Trendsetter 400/800 (TSM/MCE) are now available. See the
23 Jan 2003: UDRC included with all Trendsetter 400/800, Trendsetter Autoloader and Trendsetter Spectrum devices More...
All Trendsetter 400/800 devices (MPE and MCE) except Trendsetter NEWS and Proofsetter Spectrum are now shipped with a UDRC for debris removal. See the Debris Removal site for more information about the UDRC.
21 Jan 2003: TH1.7 does not come online on MCE device More...
Some new or replacement 1.7 thermal heads may not come online when an MCE device is powered up for the first time. A script is required to initialize the head. See the Troubleshooting page for more information.
20 Jan 2003: Trendsetter 400/800 MCE in limited Early Production More...
Trendsetter 400/800 MCE is in limited Early Production for base and Autoloader. MCE enables smaller plate size (9x12) and speed improvements.
All Trendsetter 400/800 MCE devices will be shipped with a UDRC.
All non-Quantum Trendsetter 400/800 MCE devices will be shipped with a P33 head.
Trendsetters that require Brisque Direct will be MPE devices until Brisque Direct has been qualified on Trendsetter MCE devices.
MCE hardware, firmware and other documentation has been added to the site. Check the overview page for more early production information, reference page for operator manual and training links, control/settings page for MCE firmware information, parts page for MCE parts lists.
The Escalation process is the same as for MPE but be sure to indicate whether you are reporting on an MPE or MCE machine. Serial numbers for MCE machines start with TM.
13 Dec 2002: Extra flange on some unload pans More...
Some unload table pans that were shipped in November, 2002 may have an extra flange at the rotate position. This flange may cause the rotator to jam or grind while trying to rotate. If the extra flange is detected on the unload pan (see photo 1 and 2), then the center panel (57-4687A) must be replaced.
TechPlanet CD Version 1 N.426 Oct 2002
24 Oct 2002: Replacement cables and sensors for load ramps, load tables, and unload pans More...
Fretting on contacts between cable and sensor was causing loss of connection. A new cable and sensor should be installed for improved reliability. See E897 on the FCO page for appropriate kit number and procedure.
Note: Do this FCO at the same time as E876.
11 Oct 2002: Improved cable track assembly for unload pan More...
The new track will prevent cables from getting caught in cable track links, breaking and wearing out prematurely. An adaptor plate is included in the kit to mount the new track to the unload pan and traveler. See E876 on the FCOs page for kit numbers and installation procedure.
Note: Do this FCO at the same time as E897.
11 Sep 2002: Revised specifications for Trendsetter AL More...
See the specs on the Overview page.
06 Aug 2002: This site has been restructured to fit TechPlanets common navigation More...
This site has been restructured to fit TechPlanets common navigation. If you have any questions or comments about the navigation, please contact TechPlanet feedback. For information about content in this site, please contact Janet Waterman.
29 Jul 2002: Planned Maintenance Checklist Revised More...
The picker vacuum muffler should be used to check the picker wire cable tension instead of a 14mm wrench, See Version 3 Picker, Step 6 in the Trendsetter Autoloader/NEWS Planned Maintenance Procedure.
18 Jul 2002: Unimaged Strip Seen on Positive Plates after an MPE Firmware Upgrade More...
At sites where customers use positive plates, avoid a firmware upgrade unless it is absolutely necessary. An artifact has been seen lately on Trendsetter VLFs and Trendsetter Spectrums, and it is suspected that it affects all MPE-based devices. The artifact is an unimaged strip, 0.5 to 1.0 mm wide, visible on positive plates at the away end of the plate. The solution to the problem is to downgrade to an earlier version of the MPE firmware.
If you must do a firmware upgrade because you are replacing a thermal head, or for some other reason, see the troubleshooting note for tests to verify that the plates will be free of the problem and for a possible workaround if the problem does occur.
TechPlanet CD Version 1 N.2/312 Jul 2002
12 Jul 2002: General Guidelines for F to V Speed Upgrades More...
are available on the Installation page. Check the price list or contact Steve Froese for information on specific upgrades.
28 Jun 2002: Trendsetter AL Controlled Release MPE 1.0 More...
The first Controlled Release CD is now available for the Trendsetter AL (FCO E807). A Controlled Release is a package of software/firmware components that have been tested for compatibility with each other and with Trendsetter AL hardware. All machines should be upgraded to the latest controlled release version at the next visit. For details, click on Controlled Release version 1.0 on the Control/Settings page.
03 May 2002: Power & Environmental Site Surveys More...
Creo has a contract with Rx Monitoring Services in Manchester, NH (603-666-6606 ext201) to provide Power & Environmental Site Surveys for the NAFTA region. The monitoring service includes voltage, current, temperature, humidity, dust and air pressure. Rx will provide the equipment to be installed at the customer site (for a maximum of 10 days), monitor it and send an e-mail report.
Air pressure monitoring is the latest addition to the Power & Environmental Site Survey. See Installing the Rx Air Pressure Sensor for details.
12 Mar 2002: New "Drum Tick" Firmware Command More...
Use the "drum tick" command to help troubleshoot encoder issues. For detailed instructions, see Firmware Engineering's drum tick page.
TechPlanet CD Version 1 N.115 Feb 2002
Technical Library CD Version 5.423 Oct 2001
05 Oct 2001: Output Device Name Changes More...
Changes to the output device name were announced at Print 01. For details, see Output Devices Product Overview.
Technical Library CD Version 5.323 Jul 2001
05 Mar 2000: Picker Guide Cable Routing Modification [ECO] More...
Picker guide cable routing modification. See ECO E042.
31 Dec 2000: Firmware Version 1.42 Released [FCO] More...
Release of Version 1.42 firmware to support V speed and debris removal See firmware 1.42 release notes.